Instruction Manual - Touch Screen
2011, 2848, 2860, 2872, and 2873 (32 oz. Pop-O-Golds)
PopClean Elite Popper -600 Series
2911, 2948, 2960, 2972, and 2973 (52 oz. Medallions)
Page 8
gmpopcorn.com
Setup
The Elite Series PopClean popper has been adjusted, inspected, and tested at the factory. The
Kettle is hard wired in the unit, and the exhaust filters are pre-installed and ready for use.
Installation of popper should be performed by qualified service personnel. Read and perform all
Setup steps prior to operating the unit.
1.
Remove all packaging and tape.
2.
Install unit on a level surface. Sufficient clearance is needed on the side of the popper
with the power supply cord routed from the base.
Units WITH Fire Suppression:
A
minimum 18”
(457.2 mm) clearance is required
between any opening or exhaust duct and a combustible surface, per NFPA 96
Version 2017.
Units WITHOUT Fire Suppression:
The Popper must be installed with a minimum 6”
(152.4 mm) clearance to combustibl
e surfaces on the operator’s side and
on
top of machine.
Updraft models require a minimum of 13”
(330.2 mm)
clearance on top of unit for filter access (or appropriate space for popper unit to
be moved to access filters).
3.
The unit is equipped with rolling casters. The two casters on the operator (controls)
side have a locking/unlocking feature.
4.
The main power cord is located in the cabinet base. Domestic units have a wall
receptacle provided (Twin Models have 2 plugs and 2 receptacles). A secondary,
smaller power cord, located in the cabinet base, is provided for powering the oil
dispense unit (discussed in Step 7).
Before plugging in machine, have a certified electrician install the wall receptacle and
follow all requirements listed in the Electrical Requirements section of this manual.
Units WITHOUT Fire Suppression:
Skip to Step 7.
Units WITH Fire Suppression:
With power to the unit,
the popper will NOT operate until the ANSUL
system has been charged and activated by an ANSUL Certified
Representative.
If connecting the system to the building alarm, see next step
prior to having the ANSUL system activated.
5.
If the Fire Suppression System is to be connected to the building alarm, contact a
qualified alarm system technician to make the connection prior to having the Fire
Suppression System armed. (Reference Connecting to a Building Alarm System in the
Fire Suppression System section of this manual.)
6.
Have an Ansul Certified Representative charge and activate the Fire Suppression
System (reference the Fire Suppression System section of this manual).
For a local representative, go to www.Ansul.com.
When system is activated, and the Power Switch is turned ON, the cabinet lighting and
sign will turn on. (The unit will not turn on if the fire suppression system is not activated.)
Note:
As the popper unit is plugged in (when the Fire Suppression System is armed) a
distinct click can be heard as the Fire Suppression relay kicks in.