Instruction Manual - Touch Screen
2011, 2848, 2860, 2872, and 2873 (32 oz. Pop-O-Golds)
PopClean Elite Popper -600 Series
2911, 2948, 2960, 2972, and 2973 (52 oz. Medallions)
Page 12
gmpopcorn.com
requirements). We recommend this equipment be on a dedicated and protected circuit. Failure
to wire properly will void the warranty and may result in damage to the machine. It is Gold Medal
Products Co.’s recommendation
that this machine be plugged directly into a wall outlet. The use of
extension cords is not recommended due to safety concerns, and may cause sacrificed and/or
reduced performance. Make sure cord is located to prevent a trip hazard or unit upset.
Receptacle Wiring Diagram for NEMA 14-50 (Domestic)
A certified electrician must follow the IMPORTANT instructions below for installation of the
NEMA 14-50 Receptacle (Gold Medal Item No. 82920) provided with the unit.
If the receptacle is wired incorrectly, the heat elements/kettle and other electrical components
could be at 208 or 240 V potential instead of the needed 120 V, resulting in excessive temperatures
in the heat elements (i.e.: kettle) and possible fire, and/or damage to electrical components.
Receptacle Wiring Diagram (for Export Units
–
except Australia)
A certified electrician must supply and install the required wall receptacle for this unit, follow
the IMPORTANT instructions shown.
This unit is designed to operate on single phase, 16 AMP, 4 wire supply. All electrical
components in this machine are 230 V. If the receptacle is wired incorrectly, the heat
elements/kettle and other electrical components could be at 400 V potential instead of the
needed 230 V, resulting in excessive temperatures in the heat elements (i.e.: kettle) and possible
fire, and/or damage to electrical components.
3P+N+E IEC 309 Receptacle -
Front and Back View
PE-G
L2
L1
Connect to Black
(Hot) Wire
Connect to Brown
(Hot) Wire
Connect to
Green/Yellow
(Ground) Wire
Connect to Blue
(Neutral) Wire
L3
N
Not Used
(If 5 wires provided,
connect Grey here.)
NEMA 14-50 Receptacle
- Front and Back View
Connect to Green
(Ground) Wire
Connect to Red
(Hot) Wire
Connect to Black
(Hot) Wire
Connect to White
(Neutral) Wire