Instruction Manual - Touch Screen
2011, 2848, 2860, 2872, and 2873 (32 oz. Pop-O-Golds)
PopClean Elite Popper -600 Series
2911, 2948, 2960, 2972, and 2973 (52 oz. Medallions)
Page 44
gmpopcorn.com
N7.2
Oil Pump
Cal.
Oil Pump Calibration
Sets the oil volume dispensed in 10 seconds of pump run time. The oil pump must be calibrated to
ensure accurate oil volume is dispensed. After initial configuration, the unit should not need
recalibration for normal use.
Bag-In-A-Box - Oil Pump Calibration:
For ANY calibration issues
(ex: ERROR or caught in a loop), turn unit OFF/ON and restart calibration.
Allow kettle to cool completely prior to taking volume measurements.
1.
Hold a cup under oil delivery tube
in popper.
2.
Press OK to confirm cup is in place.
3.
Press OK to dispense oil.
(Oil dispenses for 10 seconds,
continue holding cup for 1 minute
to catch drips)
Note:
If oil does not flow steadily
the first time, repeat the
process to ensure oil pump is
primed to provide an accurate
measurement.
4.
Compare oil measurement to
volume displayed.
5.
If correct amount is shown:
Press OK; then
RESTART
unit.
If needed, adjust the oil volume
shown,
then Press OK and
RESTART
unit.
Press ▲
to
increase
oil volume in 0.5 oz.
steps (up to 25.5 oz.) or,
P
ress ▼
to
decrease
oil volume in 0.5 oz.
steps (down to 0.5 oz.)
For Bucket Pump instructions, see next page.
2
3
5
Adjustment
Buttons
4
1