Self-test Error Messages
Self-test diagnostics are run:
!
During the power-on sequence.
!
After initialization by either the control panel keypad.
!
After printing.
!
When requested from the host by the ESC Q escape sequence.
(See
Programmer’s Manual
for information on escape sequences.)
The following table shows the display message, fault, and error
message. (The error message is used only when requested by ESC Q -
See note.) The fault column indicates which circuit board is defective.
NOTE
The error message is used only in the ANSI emulation while
using the serial interface. When an ESC Q escape sequence is
received, the printer performs a self-test and sends the
appropriate error message to the host if a fault is found. DCS =
ESC P and ST = ESC \. See
Programmer’s Manual
for information on
the ANSI emulation and escape sequences.
TABLE 7-6
Diagnostic Fault Codes
DISPLAY
FAULT
CORRECTIVE ACTION
Self Test
Self-test in progress.
None.
TTMI error
Invalid response from TTMI board. Call for service.
TTMI noresp
No response from TTMI board.
Call for service.
TTMI checksum
TTMI board ROM checksum failure. Call for service
Shuttle Error
Shuttle cannot stabilize.
Check for paper jam or print gap
adjustment. If either condition
does not exist, call for service.
Loading-----
Please Wait......
Self-test completed with no errors
found, printer software is loading.
None.