5000 Series User’s Manual
5-48
GEK-99044
3.
Press the
◄
(left) or
►
(right) menu browse pushbutton until the
desired option is displayed. Press the
Select
pushbutton to enable
or disable an option. The
<
symbol will immediately follow an
enabled option.
Version
This menu is used to select the Version setting for QMS. This feature
is provided for users of Code V Version I programming who utilized
rotated MAGNUM characters. Elongation of characters could cause
print line length to be exceeded. Setting this option to Ver I, will
prevent character elongation from causing print line overflow.
Use the following procedure to select this option:
1.
While in the
QMS
menu, press the
◄
(left) or
►
(right) menu
browse pushbutton until
Version
is displayed in the lower right
corner of the LCD.
2.
Press the
▼
(down) menu browse pushbutton to access the
Version
options.
3.
Press the
◄
(left) or
►
(right) menu browse pushbutton until the
desired option is displayed. Press the
Select
pushbutton to enable
or disable an option. The
<
symbol will immediately follow an
enabled option.
Magnum Spaces
This menu is used to select the Magnum Spaces setting for QMS.
When Magnum Spaces is enabled, trailing spaces in strings are
ignored. If a Magnum pass field contains only spaces, the defined
height of the field is ignored.
Use the following procedure to select this option:
1.
While in the
QMS
menu, press the
◄
(left) or
►
(right) menu
browse pushbutton until
Magnum Spaces
is displayed in the
lower right corner of the LCD.
2.
Press the
▼
(down) menu browse pushbutton to access the
Magnum Spaces
options.
3.
Press the
◄
(left) or
►
(right) menu browse pushbutton until the
desired option is displayed. Press the
Select
pushbutton to enable
or disable an option. The
<
symbol will immediately follow an
enabled option.
Ignore Chr Mode
This menu is used to select the Ignore Character Mode setting for
QMS. When Ignore Chr Mode is enabled, the character value
specified in Ignore Char option will be discarded when detected in the
datastream. If this option is enabled, a character must be designated
to be discarded using the Ignore Char (see next option.)
1.
While in the
QMS
menu, press the
◄
(left) or
►
(right) menu
browse pushbutton until
Ignore Chr Mode
is displayed in the
lower right corner of the LCD.
Version
Ver I<
QMS
Version
Version
Disable<
QMS
Magnum Spaces
QMS
Ignore Chr Mode