5000 Series User’s Manual
GEK-99044
6-4
5.
Use the (left) or (right) menu browse pushbuttons to adjust
the amplitude while the pattern is printing.
6.
Press the
Clear
pushbutton to stop printing the pattern.
7.
Press the (left) or (right) pushbutton until
Save Amplitude
is
displayed in the lower right corner of the LCD.
8.
Press the
Select
pushbutton to save the amplitude adjustment.
HEADSERVICE
This menu is used to check the amount of usage for the individual
print heads and to reset the print head counters. The printer keeps
track of how many times each print head is fired during printing and
displays this information on a graph.
Use the following procedures to select this option:
1.
While in the
Maintenance
menu, press the (left) or (right)
menu browse pushbutton until
HeadService
is displayed in the
lower right corner of the LCD.
2.
Press the
Select
or (down) menu browse pushbutton to access
the
HeadService
options.
The following describes the options available:
Dot Counts
This menu is used to reset the print head counters. The counters for
the print heads can be reset to zero. This procedure is normally used
after the installation of a new print head. Resetting this counter
arbitrarily is not recommended.
Note
Make sure the correct print head number is displayed before
clearing the counter.
Once a counter is reset to zero, it cannot
be set back to its original count.
AdjustAmplitude
Save Amplitude
Maintenance
HeadService
SAMPLE OF AMPLITUDE PATTERN
BAD
ALIGNMENT
BAD
ALIGNMENT
PERFECT
ALIGNMENT