5000 Series User’s Manual
GEK-99044
6-8
Note
Repeat this section if further changes are necessary. The valid
range of values for EOL Limit is between 30 and 120. The valid
range of values for EOL Warning is between 0 and 29.
The EOL Limit allows the use to set the End of Life Limit value
for the Ribbon. Although, the user can set a limit other than the
EOL recommended for a ribbon, the current EOL types available
are as follows:
5050/5100 (55 or 60 dBa) Cabinet Model
50M and 75 M
5180 (52 and 55 dBa) Cabinet Model
75M and 125M
The EOL Warning allows the user to set the End Of Life Warning
value for the ribbon. This warning does not cause a fault. It is a
monitoring function only.