Troubleshooting
Model: FSH-2, FSH-2A-99
6-01.
Troubleshooting Procedures - continued
Problem
Probable Cause
Corrective Action
Fryer will not power-up:
•
[HOOD POWER]
light
ON
•
[
FILTER MISSING]
light
ON
•
[FRYER POWER]
light
OFF
a. Baffle filter is missing or not
properly installed
Install filter / check positioning.
b. Charcoal filter is missing or not
properly installed
Install filter / check positioning.
c. Faulty filter switches.
Test & replace as needed.
Fryer will not power-up:
•
[HOOD POWER]
light
ON
•
[
FILTER MISSING]
light
OFFN
•
[FRYER POWER]
light
OFF
• No alarm sounding
a. Fire Suppression system is not
armed.
Contact Ansul service company.
b. Ansul switch is faulty
Contact Ansul service company.
Fryer will not power-up:
•
[HOOD POWER]
light
ON
•
Continuous (steady) tone
alarm
sounding.
•
[FRYER POWER]
light
OFF
a. Baffle or charcoal filter clogged Replace charcoal filter with new •
Clean baffle filter.
b. Hood exhaust outlet excessively
block
Clear of any obstructions.
c. Vacuum switch is out of
adjustment
Test & adjust vacuum switch.
d. Kinked or blocked vacuum line Remove vacuum line kinks or
blockage.
e. Fan running slow or blades are
loaded with grease build-up.
Check voltage and inspect blower;
clean if needed
Fryer will not power-up:
•
[HOOD POWERED]
light
ON
•
[WASH]
light
ON
•
Intermittent (beeping) tone
alarm
sounding.
•
[FRYER POWER]
light
OFF
a. Excessive grease film built up on
collector fins; too dirty
Clean the EAC cell,
Section 4.04.2
.
b. EAC cell is not installed
Install clean EAC cell.
c. EAC driver board is faulty
Test & replace EAC power supply if
needed.
d. Poor connection at contact
plate; dirty contacts, mis-
alignment, faulty contacts.
Check cell position, clean contacts,
inspect contact plate & replace if
needed.
e. Ionizer wire(s) missing
Replace missing wire(s)
Fryer is ON:
•
[HOOD POWER]
light
ON
•
[CHECK]
light
ON
•
No
alarm sounding, but cell is
NOT
cleaning air
.
a. Ionizer wire broken & touching
chassis.
Replace ionizer wire.
b. Collector fins shorted to ground
by moisture.
Dry cell, determine cause of
moisture, cool air being drawn into
hood creating condensation.
Содержание FSH-2
Страница 2: ......
Страница 4: ......
Страница 28: ...18 Installation Model FSH 2 FSH 2A 99 ...
Страница 36: ...26 Overview Model FSH 2 FSH 2A 99 ...
Страница 45: ...35 Operation Model FSH 2 FSH 2A 99 NOTES ...
Страница 46: ...36 Operation Model FSH 2 FSH 2A 99 ...
Страница 58: ...48 Parts List Model FSH 2 FSH 2A 99 1 2 3 5 6 8 7 4 Not shown 7 02 Ventless Hood Front ...
Страница 64: ...54 Parts List Model FSH 2 FSH 2A 99 Notes ...
Страница 65: ......