21
Overview
Model: FSH-2, FSH-2A-99
Item
Description
Function
*
1
Filter Access Cover
Provides access to the filter chamber and plenum area.
Hood will not operate unless this cover is in place and
properly latched.
2
Charcoal Filter
Helps to control undesirable aromas generated during
cooking. It should be replaced monthly (approx).
NEVER
attempt to clean filter
.
Keep a spare filter
(Giles #30248)
for
quick exchange to avoid lost time!
NO FILTER COMPLETELY ELIMINATES COOKING ODOR.
3
Electronic Air Cleaner (E.A.C.)
Collection Cell
The E.A.C. system is an electronic air cleaner that
electrostatically captures grease-laden vapor and smoke
particulate generated by cooking.
Power must be turned
OFF before removing the EAC Cell for cleaning. To maintain
best air cleaning performance, the cell must be cleaned
daily. Fryer under hood will be disabled if EAC Cell is
missing, excessively dirty, or experiencing other faults.
**
4
HEPA Filter
(CE or Optional)
CE listed models or as option
: EAC system is replaced by a
high-efficiency
HEPA Filter
. The filter
CANNOT
be cleaned
and must be replaced periodically to maintain acceptable
performance.
Fryer under hood will be disabled if the HEPA
Filter is missing or becomes clogged. Location of a HEPA
Filter is reverse of what is shown ... charcoal filter will be
below the HEPA filter.
5
Baffle Filter
First stage of the air cleaning system. Easily removed for daily
cleaning.
To prevent contact with electrical parts and avoid
electrical shock,
DO NOT
remove the baffle filter while hood
and fryer are powered.
6
Grease Drip Cup
Captures and contains grease condensate generated by the
baffle filter. It should be cleaned daily, or as needed.
7
Grease Drip Cup Safety Pin
Secures the grease drip cup in place to prevent it from
unintentionally falling from the holding bracket.
8
Discharge Air Diverter Stack
Diverts hood exhaust discharge air to the sides and rear.
Allows for operation of the unit in spaces with lower ceiling
heights.
9
Appliance Detector Link
Detects fire in the fryer and trips the fire extinguishing
system. Be careful not to hit or bump this link. Doing so
may cause the fire extinguishing system to inadvertently
discharge.
*
Not Shown
**
CE Listed Models require HEPA Filter
3.01
Filter Chamber & Hood Front
Содержание FSH-2
Страница 2: ......
Страница 4: ......
Страница 28: ...18 Installation Model FSH 2 FSH 2A 99 ...
Страница 36: ...26 Overview Model FSH 2 FSH 2A 99 ...
Страница 45: ...35 Operation Model FSH 2 FSH 2A 99 NOTES ...
Страница 46: ...36 Operation Model FSH 2 FSH 2A 99 ...
Страница 58: ...48 Parts List Model FSH 2 FSH 2A 99 1 2 3 5 6 8 7 4 Not shown 7 02 Ventless Hood Front ...
Страница 64: ...54 Parts List Model FSH 2 FSH 2A 99 Notes ...
Страница 65: ......