The
HEPA Filter
is a consumable item which must be replaced periodically (see
Sections 4.02.5, Removal & 4.02.5,
Installation
).
It CANNOT be cleaned and reused.
Typical replacement cycle can vary significantly depending on the
cooking activities (quantity and types of food cooked each operating day). A
HEPA
filter should probably have a useful
service life of approximately
3 to 4 months
, depending on usage.
If a
HEPA
filter has been in service for a period of time and a clogged filter alarm condition occurs
(see Section 4.03.2)
,
first replace the charcoal filter. If the alarm clears, that is an indication that the
HEPA
filter if still serviceable. Should the
alarm
NOT
clear with the new charcoal filter, the filter probably needs to be replace.
DO NOT attempt to clean and
reuse the HEPA filter.
Use
GILES
replacement
Item No. 41254
. Write the replacement date on new filter.
IMPORTANT: Failure to use Giles OEM parts and OEM replacement filters may void the factory warranty.
5.01.4
HEPA Filter Maintenance [FSH-2A-99; HEPA MODEL ONLY]
The
FSH-2A-99 Hood
is available equipped with a replaceable
HEPA Filter
as an alternative to the electronic air cleaning
(E.A.C.) system with sustainable collector cell.
5.02
General Hood Cleaning
DO NOT
wash down Hood with water from a spray hose.
DO NOT
steam clean or use any type pressure washing equipment.
DO NOT
use products containing chlorine or other caustic chemicals.
DO NOT
use abrasive products, steel wool or scouring pads.
The factory-recommended product to use for general cleaning/degreasing of this equipment is
Simple Green® Crystal
Foaming Spray Cleaner/Degreaser
, a readily available, biodegradable, non-toxic effective degreasing cleaner
.
Following sections describe procedures for general Hood cleaning.
40
Cleaning & Maintenance
Model: FSH-2, FSH-2A-99
Charcoal Filter is a single-use, disposable filter. NEVER attempt to clean and reuse; doing so
can cause damage to the unit.
Charcoal filter is a consumable item which must be replaced periodically (see
Sections 4.02.6, Removal & 4.02.7,
Installation
). It
CANNOT
be cleaned and reused. Typical replacement cycle is every
30 to 40 days
, depending on usage.
Use
GILES
replacement
Item No. 30248
. Write the replacement date on new filter.
IMPORTANT: Failure to use Giles OEM parts and OEM replacement filters may void the factory warranty.
5.01.3
Charcoal Filter Maintenance
Continued on Next Page
Содержание FSH-2
Страница 2: ......
Страница 4: ......
Страница 28: ...18 Installation Model FSH 2 FSH 2A 99 ...
Страница 36: ...26 Overview Model FSH 2 FSH 2A 99 ...
Страница 45: ...35 Operation Model FSH 2 FSH 2A 99 NOTES ...
Страница 46: ...36 Operation Model FSH 2 FSH 2A 99 ...
Страница 58: ...48 Parts List Model FSH 2 FSH 2A 99 1 2 3 5 6 8 7 4 Not shown 7 02 Ventless Hood Front ...
Страница 64: ...54 Parts List Model FSH 2 FSH 2A 99 Notes ...
Страница 65: ......