SECTION 4 - INSTALLATION
4
Dedicated High-Speed Field Wiring (Non-POS) Instructions (DCM2.2
only)
To install the dedicated High-Speed, proceed as follows:
Connect the M02993A006 Dedicated High-Speed Cable from port P333 on DCM2.2 to the dedicated
high-speed connection from the backroom as shown in
Figure 23: Generic Type Configuration
The following table lists wiring details for Generic mode:
Cable Part
Connector
Color
Description
M02993A005
P300.1
Red
CRIND+
M02993A005
P300.3
Yellow
CRIND-
M02993A006
P333.1
Yellow
High Speed
M02993A006
P333.2
Yellow
High Speed
M02993A006
P333.3
Red
Pump+
M02993A006
P333.4
Blue
Pump-