27
SECTION 4 - INSTALLATION
4
MDE-5222F
5 Replace the 24 VDC M07973A006 Power Cable in place of M07973A004 and make the following
connections:
• Connect P305 to J305.
• Connect J401 to P301 on the DCM2.2 assembly.
• Connect power to each CRIND (J301A to P301A/B and J301B to P301A/B).
Figure 11: Connecting Cables to DCM2.2 Assembly
ZMODEM* Serial
Connection to Pump
P302B Serial
Connection to
Side B Door
P300 Pump and
CRIND Two-Wire
to High Speed
P306 Two-Wire
Connection to Pump
P333 Dedicated
High Speed
Audio and video Cables
from Side B Door to
GSOM
Ethernet Connection
Audio and video
Cables from
Side A Door to GSOM
High Speed (HomePlug)
Jumper
P302A Serial Connection
to Side A Door
P301 Power Cable
Jumper Configured
for Generic and MOC
mode Selection
P306B Power Cable
P304A
Backroom
Ethernet
Connection
Backroom
Connection
Laptop Service Port
P306A Power Cable
Note: * ZMODEM is for Encore 500 only.
DCM2.2 Connectors
The following table lists the port numbers and functions of DCM2.2 connectors:
DCM2 Connector Port Number
Function
3-pin MTA .156”
P301
24 VDC power input
2-pin MTA .156”
P306A
24 VDC power output (fused). This is primarily
used to power the DCM in Applause Media
System.
5-pin MTA .100”
P300
Two-wire from D-Box [CRIND and Pump
(Generic only)].
2-pin MTA .100”
P303
Two-wire connection to PCN
8-pin MTA .100”
P302A
RS-232 pump and CRIND to PIP3 A
4-pin
P333
Dedicated Home Plug
8-pin MTA .100”
P302B
RS-232 pump and CRIND to PIP3 B
Содержание FlexPay IV CRIND
Страница 1: ...MDE 5222F December 2018 FlexPay IV CRIND Retrofit Kit Installation Instructions for Encore 300 500...
Страница 2: ...This page is intentionally left blank...
Страница 8: ...MDE 5222F 4 SECTION 1 INTRODUCTION 1 This page is intentionally left blank...
Страница 50: ...MDE 5222F 46 SECTION 4 INSTALLATION 4 This page is intentionally left blank...
Страница 59: ...55 SECTION 6 APPENDICES MDE 5222F 6 Figure 7 Cable Block Diagram for FlexPay IV DCM2 2...