31
SECTION 4 - INSTALLATION
4
MDE-5222F
Connecting AFP/DCM2 Power Supply
There are three power supply scenarios:
• Encore 300:
M04161B001 Power Supply is provided with the kit and the printers connect to the fuse
board on the same AFP/DCM2 assembly.
•
Encore 500:
- Powered by Switching Power Supply (M04161B001), and the printers remain connected to the
M07121 Board.
- Powered by M02274 Power Supply Assembly, and additional power supply and fuse board
required.
Note: If the FlexPay IV CRIND Retrofit Kit includes the optional Insite360 Encore Power Supply, refer to
MDE-5349 Insite360 Encore Power Supply Retrofit Kit Installation Instructions (included) for power
supply installation instructions.
Encore 300/500: Phoenix Power Supply (Older Supply)
For these cases, a supplementary power supply is included.
•
Upgrading to 10.4-inch and Encore 500 is powered by Phoenix supply:
Cable AC Power Distribution
Cable (M04406A001) is provided in the kit to provide an AC harness. Route the same as above
M04406A001 inside the U-channel. Plug the black and white AC power cable from the supplementary
supply in the AC harness.
•
Encore 500 with M02274 Power Supply
: M12777A003 Cable is provided in the kit. Connect it to the
spade lugs inside the supply. Route the cables with the female mates down the length of the
U-channel. Plug the black and white AC power cable from the supplementary supply in the AC
harness.
•
Encore 300 or Encore 500 with M02274 Power Supply
: The M02274 supply has an AC harness
standard. Plug the black and white AC power cable from the supplementary supply in the AC harness
To connect the cables:
- Connect P301A/B of M13120A001 on side A to J301A of M12777A003.
- Connect P301A/B of M13120A001 on side B to J301A of M12777A003.
Содержание FlexPay IV CRIND
Страница 1: ...MDE 5222F December 2018 FlexPay IV CRIND Retrofit Kit Installation Instructions for Encore 300 500...
Страница 2: ...This page is intentionally left blank...
Страница 8: ...MDE 5222F 4 SECTION 1 INTRODUCTION 1 This page is intentionally left blank...
Страница 50: ...MDE 5222F 46 SECTION 4 INSTALLATION 4 This page is intentionally left blank...
Страница 59: ...55 SECTION 6 APPENDICES MDE 5222F 6 Figure 7 Cable Block Diagram for FlexPay IV DCM2 2...