MDE-5222F
8
SECTION 3 - REMOVING COMPONENTS
3
TRIND Board and Call Button Assembly (if Applicable)
Note: For upgrading a unit that previously had no CRIND, disregard the steps for removing old CRIND
components (except the door node or main display) and proceed with the installation of the new
CIM door, printer, and AFP/DCM2 in
“FlexPay IV CRIND Retrofit Kit”
.
To remove the TRIND board and call button assembly:
1
For units equipped with TRIND, remove the two screws that secure the TRIND board to the door.
Notes: 1) Remove all the cabling for TRIND and the TRIND card cage from the unit.
2) Remove the barcode scanner, if applicable.
2
For units with call button option, remove the call button assembly by removing the two screws and
disconnecting the cables.
3
Remove any other options available.
4
Remove the existing cables for CRIND logic located on the UL bucket.
Notes: 1) The existing UL bucket will be reused. It contains the UL label and serial number information.
Extender brackets are provided in the kit to slightly alter the location of the UL bucket.
2) Encore 500 units may not contain a UL bucket. If not, a UL bucket or a modified UL bucket is
provided in the kit for mounting components such as the intercom PCB for Applause Media
System.
5
Remove the door node (Encore 500)/main display (Encore 300) from the CIM door.
Содержание FlexPay IV CRIND
Страница 1: ...MDE 5222F December 2018 FlexPay IV CRIND Retrofit Kit Installation Instructions for Encore 300 500...
Страница 2: ...This page is intentionally left blank...
Страница 8: ...MDE 5222F 4 SECTION 1 INTRODUCTION 1 This page is intentionally left blank...
Страница 50: ...MDE 5222F 46 SECTION 4 INSTALLATION 4 This page is intentionally left blank...
Страница 59: ...55 SECTION 6 APPENDICES MDE 5222F 6 Figure 7 Cable Block Diagram for FlexPay IV DCM2 2...