MDE-5222F
60
SECTION 6 - APPENDICES
6
To verify the cable connections:
Power Cabling
Ensure that the power cables are connected as follows:
1
PIP board
: P220 port is connected to +24 V Cable (M14340A001).
2
UPM board
: P1 port is connected to +24 V cable.
3
AFP board
: P301 port is connected to +24 V cable.
PIP3 Board Cabling
Ensure that the PIP3 board cables are connected as follows:
1
PIP3 USB uplink port is connected to the USB Cable (M03695B004) and connected to the P4 port on
the UPM.
2
P213 port of PIP3 is connected to the M13119 Cable, which connects to the UPM P2.
3
P211 port is connected to the Speaker Cable (M09259A004) and to the left speaker.
4
P212 port is connected to the Speaker Cable (M09259A004) and to the right speaker (if equipped).
5
P205 port is connected to M14136A00X Cable and to UPM P5.
6
P206 port is connected to 10.4-inch LVDS Cable (M13722A002) and to 10.4-inch display.
7
P207 port is connected to 5.7-inch Parallel Cable (M9224B001) and to 5.7-inch display.
8
P209 port is connected to 10.4-inch Backlight Cable (M9224B001) and to 10.4-inch display.
9
P210 port is connected to 5.7-inch backlight leads from the 5.7-inch display.
Содержание FlexPay IV CRIND
Страница 1: ...MDE 5222F December 2018 FlexPay IV CRIND Retrofit Kit Installation Instructions for Encore 300 500...
Страница 2: ...This page is intentionally left blank...
Страница 8: ...MDE 5222F 4 SECTION 1 INTRODUCTION 1 This page is intentionally left blank...
Страница 50: ...MDE 5222F 46 SECTION 4 INSTALLATION 4 This page is intentionally left blank...
Страница 59: ...55 SECTION 6 APPENDICES MDE 5222F 6 Figure 7 Cable Block Diagram for FlexPay IV DCM2 2...