You have to operate the elimination of the materials in conformity with the regulations in force. All materials must be
divided by type (copper, aluminium, plastic, electrical parts, etc.).
DEMOLITION
UK
UK
In order to move away the automation, follow these instructions:
1 - Cut off the power supply and disconnect the electrical installation;
2 - Dismantle the control console and all the other components of the installation.
If you have noticed that some components have been damaged, you have to replace them.
The gearmotor AGO is designed and built for the opening of gates with max of 5 m leaf or weight max. 300Kg.
Gi.Bi.Di. Srl assumes no responsibility for a purpose other than that provided by gearmotor AGO.
Since automation can be put into motion in view by button or remotely by remote control, it is essential to check
frequently the perfect efficiency of all safety devices.
It is advisable to check periodically (every six months) the regulation of electronic friction of which must be equipped
the electronic control board.
For the installation of the automation, the following equipment is required: wrenches, screwdriver, metre,
bubble level, saw, drill, welding machine.
1 - Read carefully the instructions enclosed in this manual.
2 - Make sure that the gate has a rather solid structure and that there is no friction points in its movement.
3 - Make sure that the leaf is suitably balanced, even after the installation of the gear motor.
4 - Check that the electrical installation is in accordance with the characteristic required by the gear motor.
DISMANTLING
USE OF THE AUTOMATION
EQUIPMENT
PRELIMINARY CHECKS
TECHNICAL DATA
AGO 400
AGO 624E
AGO 424E
AGO 600
Maximum length of the gate
Maximum weight of the gate
Stroke
Power
Power supply
Absorption
Max. thrust
Operating temperature
Opening time
Use frequency
Thermal protection
Lubrication
4.0 m
5.0 m
300 kg
40 cm
330 W
220/230 V
1.5 A
1600 N
-25°C +60°C
22 sec.
30%
150°C
Grease
300 kg
60 cm
180 W
220/230 V
1.5 A
1600 N
-25°C +60°C
33 sec.
30%
150°C
Grease
5.0 m
250 kg
60 cm
70 W
24 Vdc
0.5 - 5.5 A
1500 N
-25°C +60°C
33 sec.
90%
-
Grease
4.0 m
250 kg
40 cm
70 W
24 Vdc
0.5 - 5.5 A
1500 N
-25°C +60°C
22 sec.
90%
-
Grease
SCHEDULED MAINTENANCE
Description
Photocells cleaning
Control of gate hinges and supports,
balancing of the gate
Controlling the sensitivity of
electronic friction (torque adjustment)
of the control board
Controlling degree of protection
Monitoring current dispersion
Control of signals
Frequency
Monthly
as needed
Semiannual
Semiannual
Annual
Semiannual
Entrusted
Operator
Operator
Technician
Technician
Technician
Operator
Operation
Clean with damp cloth
Check the status of welds and
corrosion.
Unhook the engine and check the
balancing and the eventual points
of friction
Check the adjustment of the couple
as described in EN 12453 - EN 12445
Check that there are no traces of
moisture or water inside electrical
casings
Verify that the safety warning signage
is complete and intact
Verify that the dispersion of current is
less than 7.5 A