25
P U L L - T O - O P E N
© G h o s t C o n t r o l s
®
2 0 2 1
CONNECTING OPERATOR ARM TO CONTROL BOX
STEP 9.
Insert the operator cable into the control box.
A. Route the operator cable through the same
strain relief as the battery harness cable and
into the control box.
B. Connect the operator wires to the control
board. Find the 1st operator screw terminal
on control board and insert the red, black,
green and white wires (left to right) into the
matching color coded terminals and tighten
each of the screws so that the wires do not
come loose and fall out.
*You will connect the second operator wires
later into the 2nd operator screw terminal.
C. Make sure wires are not inserted too far into
the terminal slots and that the wire insulation
is not interfering with contact to the system
control board.
D. Tighten strain relief nuts on the control box
to close the seals around the wires.
B