UFO-NT
58
Service menu
Name
1 Sub-menu
2 Sub-menu
3 Sub-menu
Explanation
SIO manual
not active
active
Safety sensor "open" (SIO) not
active during manual opening.
Bolt contact
type
current state
Bolt contact type
Z-> not active
K-> NO contact
F-> Lock contact
Lock contact
type
NO contact
NC
Feedback e.g. of a motor lock
KB
current state
KB
Z-> not active
K-> NO contact
KB contact type not used
NO contact
NC
The input KB is active in the AU,
LS and NA modes of opera-
tion. With 2-leaf assemblies the
mechanical contact can be con-
nected to the active leaf control
or to the passive leaf control.
Upon activation, the active leaf
opens and, if switched on, the
passive leaf opens. During ac-
tivation, the output of the me-
chanical contact is closed (24 V
applied at the KB input). Active
in every mode of operation
when the door is not closed.
KI
current state
KI
Z-> not active
K-> NO contact
A->*0.1s
KI contact type not used
NO contact
NC
The input KI is active in AU and
LS mode. With 2-leaf assemblies
the contact sensor inside can
be connected to the active leaf
control or to the passive leaf
control. Upon activation, the ac-
tive leaf opens and, if switched
on, the passive leaf opens. Ac-
tive in every mode of operation
when the door is not closed.
KI delay
Value 0 s *0.1
min
0 s *0.1
Max. 90 s *0.1
Only active when the door is in
a closed position.
KA
current state
KA
Z-> not active
K-> NO contact
A->*0.1s
KA contact type not used
NO contact
NC
The KA input is only active in
the AU mode of operation. With
2-leaf assemblies the contact
sensor outside can be connect-
ed to the active leaf control or
to the passive leaf control. Upon
activation, the active leaf opens
and, if switched on, the passive
leaf opens. Active in every mode
of operation when the door is
not closed.
KA delay
Value: 0 s *0.1
min
0 s *0.1
Max. 90 s *0.1
Only active when the door is in
a closed position.
NA
current state
NA
Z-> not active
K-> NO contact
Содержание UFO-NT F
Страница 1: ......
Страница 7: ...UFO NT 7 Supply terminals 4 Supply terminals DCU800 1 2 24V GND 6 1 RS485 passive leaf 2 FREE ...
Страница 79: ...UFO NT 79 ...