UFO-NT
38
Mode of operation
Mechanical programme switch (MPS-D)
à
MPS-D, AS500, mat. no. 118417
à
MPS-D-ST, with key, AS500, mat. no. 118418
à
Accessories:
Surface-mounted cap, single, AS500, mat. no. 120503
à
For 2-leaf systems, the MPS-D is connected to the active
leaf.
à
Set the parameter Contact type (if changed), with:
à
DPS:
Setting not possible.
à
ST220: Set the "Signals", "Input signals", "AU", "Contact
type" to " NO contact " and "DO", "Contact type"
to " NO contact " (default settings).
Set "NA", "Contact type" to "NC".
3
2
1
0 OFF
8 AU
9 DO
6 NA
7 LS
2 24V
4
DPS (DPS) with OFF
à
AS500, DPS with OFF, flush-mounted,
alpine white,
mat. no. 151524
à
Operating modes: OFF, NA, LS, AU, DO,
1-leaf/2-leaf opening
X
Observe the installation instructions.
à
DPS cannot be connected if the PE2 or
PE3 function is set to "MPS" (only display
possible).
X
Connect DPS to the active leaf.
à
Changing the mode of operation with the
DPS is only possible if 24 V is not applied
to NA, LS, AU, DO or to PE2 or PE3, if PE2
or PE3 is configured to OFF, 2-leaf opening
or 1-leaf opening. After reconnection to
the mains, the drive is in the previously set
mode of operation.
à
It is possible to change the mode of op-
eration if the key switch is active or with
jumper 1-44.
2
1
1
44
41
42
GND
1
2 24V
42 RS485-A
41 RS485-B
SCR
43
RS485
100 mA
OFF
2
1
20 KB
3 24V
KB
3
1
Display 1-leaf/2-leaf operation
(LED lights up at 1-leaf operation)
2
Concealed service push button
3
Additional contact in the key switch for activation of KB
à
Switching over between 1-leaf and 2-leaf operation:
X
Press the
keys simultaneously.
Operation at the DPS is not possible during the self-test, e.g. after changing the mode of operation.
The control can be configured using DPS.
Accessing the service menu:
X
Simultaneously press the hidden service key and
.
Accessories:
à
AS500, DPS with OFF and SCT, without euro profile half cylinder, flush-mounted, alpine white, mat. no. 155810
à
Key switch SCT, single-pole, flush-mounted, AS500 without euro profile half cylinder, mat. no. 117996
à
Euro Profile half cylinder, mat. no. 090176
à
Additional contact, mat. no. 024467
à
Surface-mounted cap, single, AS500, mat. no. 120503
à
Surface-mounted cap, double, AS500, mat. no. 128609
Содержание UFO-NT F
Страница 1: ......
Страница 7: ...UFO NT 7 Supply terminals 4 Supply terminals DCU800 1 2 24V GND 6 1 RS485 passive leaf 2 FREE ...
Страница 79: ...UFO NT 79 ...
Страница 80: ......