UFO-NT
37
Mode of operation
à
ST220:
à
Set "PE1" or "PE2" to "WC control".
à
Set "PA1" or "PA2", "Function" to "Exit only".
à
Set "PA1" or "PA2", "Function" to "WC control alarm".
à
Set "Hold-open time, "1-leaf opening" to the desired time (0–60 s).
Accessories:
à
Plastic elbow switch, white, mat. no. 114078
à
Plastic elbow switch, stainless steel, mat. no. 114077
à
Stainless steel elbow switch, mat. no. 119898
à
Stainless steel elbow switch LS 990, surface-mounted, mat. no. 128582
à
Stainless steel elbow switch LS 990, flush-mounted, mat. no. 128583
à
SLE220 indicator lamp, flush-mounted, AS500, AW, mat. no. 115934
Optional accessories:
à
SLH220, signal horn, ASW500, AW, complete, mat. no. 115939
Emergency shut-off switch
See chapter 6.1 "Key switch".
16 Mode of operation
The modes of operation are described in the Powerturn user manual.
à
To operate the DPS DPS see chapter 27.4 "DPS (DPS)".
à
To operate the service terminal ST220 see chapter 27.1 "Service terminal ST220".
à
Setting and operation using
à
Service button
à
Mode of operation button
The state of the drive to which the ST220 is connected is displayed.
X
Press the
button.
X
Select "Active leaf para" or "Passive leaf para" using the
or
key and press the
key.
For further settings, see the descriptions below.
16.1 Programme switch
Mechanical programme switch (MPS)
à
Connection to PE2 or PE3
à
MPS, AS500, mat. no.113226
MPS-ST, with key, AS500, mat. no. 113227
à
Modes of operation
OFF, NA, LS, AU 1-leaf, DO, AU 2-leaf
à
Follow the installation instructions
à
Accessories:
Surface-mounted cap, single, AS500, mat. no. 120503
à
For 2-leaf systems, the MPS is connected to the active leaf.
à
If the MPS is used, the mode cannot be changed with DPS or via the
NA, LS, AU and DO inputs.
à
Set the parameters of the control to which the MPS is connected,
with:
à
DPS:
Set
e2
or
e3
to
01
(MPS).
Set
a2
or
a1
to
0 4
(Fault display for MPS).
à
ST220: Set "Signals", "Input signals", "PE2", "PE2 function" or
"PE3", "PE3 function" to "MPS" and "Signals", "Output
signals", "PA2", PA2 function" to "MPS fault".
GND
1
2
24V
51
PE1
52
PE2
PA2
57
57 2
52
PE1 PE2 - GF
PA1 P A2 - GF
1
53
PE3
oder
1
The LED at the MPS lights up in case
of a fault and when maintenance
is due; the light also blinks during
maintenance.