Configurable outputs
Drive-side supplied electric strike
1
Free swing diode 1N4007, mat. no. 115293
2
Wire jumper
1
2
GND
1
2
24V
55 PA1A
56 PA1B
PA
PA2
57
Customer-supplied electric strike
à
Contact load output PA1 at 12 V AC: max. 1 A
~ 12V AC ~
max. 1A
GND
1
2
24V
55 PA1A
56 PA1B
PA
PA2
57
Bolt message (RM)
See chapter 13 "Electric strike", "Bolt message".
12.1.6 Door status message
à
The function is used to signal the door status, e.g. to a customer building control centre.
à
Message function/door mode:
08 Closed and locked
09 Closed
10
Not closed
11 Open
12 Off
13 Night
14
Exit only
15 Automatic
16
Hold open
18
Day/Night changeover
20
Maintenance due (see chapter 12.1.9)
à
Set the parameters with:
à
DPS: Set
a1
to the desired message function.
à
ST220: Set "PA1 function" to the desired message function.
1
Building control centre (provided by customer)
2
Signal input
PA
55
PA1A
56
PA1B
2
1