GENERAL DESCRIPTION
E
N
G
L
I
S
H
9
During operation, the activation of the heating or cooling mode is indicated in the
following way:
Heating
The
symbol indicates that the activation command has
been sent to the command actuator of the boiler or area
solenoid valve. If the timed thermostat does not receive
confirmation of effective implementation from the actuator,
the
symbol will begin to flash. Subsequently, the timed
thermostat sends the activation command every 60 seconds
until it receives confirmation.
Cooling
The
symbol indicates that the activation command has
been sent to the command actuator of the air-conditioner or
area solenoid valve. If the timed thermostat does not receive
confirmation of effective implementation from the actuator,
the
symbol will begin to flash. Subsequently, the timed
thermostat sends the activation command every 60 seconds
until it receives confirmation.
Operation with active fan coil control
If the fan coil control function has been activated, the
display will show the
symbol. In addition, you will be
offered the page on which you can manually alter the fan
coil speed or set the AUTO mode (whereby the fan coil
speed is automatically adjusted on the basis of the
difference between the setpoint fixed on the device and the
detected temperature).
Timed thermostat operation statuses
The timed thermostat has four distinct operation statuses:
- Normal operation
- Parameter setting
- Hourly profile programming
- Easy channel localisation mode
When it is switched on, the timed thermostat goes into “normal operation” status. Using
the
button key, you can switch from one status to another. The switchover from
“parameter setting” status, “hourly profile programming” status” or “Easy channel
localisation mode” to “normal operation” status also comes about automatically, 30
seconds after the last pressure on the button keys.