E
N
G
L
I
S
H
17
Back-lighting intensity
Use the
or
button key to choose how to manage the
back-lighting intensity (MAN = fixed value; SENS = light
sensitive sensor). This parameter is only visible if the back-
lighting is active. If the type of management is MAN, use
the
or
button key to choose the required percentage
of light intensity (the gap can be set from 30 to 100%).
If the type of management is SENS, use the
or
button
key to increase (+10%), decrease (-10%) or leave unaltered
(0%) the intensity value detected by the built-in light-
sensitive sensor. To confirm your choice and move on to
the next parameter, press the
button key within 30
seconds.
External temperature probe sensor
Use the
or
button key to set the function of the NTC
temperature probe sensor connected to the timed
thermostat (OFF = disabled; TEMP = enabled as
temperature probe; FLO = enabled as underfloor probe). To
confirm your choice and move on to the next parameter,
press the
button key within 30 seconds.
Impact of the external temperature probe sensor on the
measured temperature calculation
Use the
or
button key to set the weight (%) of the
external temperature probe sensor in the calculation of the
temperature measured by the timed thermostat (the value
can be set from 10% to 100%, in steps of 10). This
parameter is only visible if the NTC temperature probe
sensor connected to the timed thermostat has been enabled
as a temperature probe on the previous screen. To confirm
your choice and move on to the next parameter, press the
button key within 30 seconds.
USER INSTRUCTIONS