background image

5 YEAR 
LIMITED 
WARRANTY*

Innovation made simple...

SM

INSTRUCTION MANUAL

TSH-2

3 H 2 COOLING

HU DUAL FUEL READY

Содержание TSH-2 TrueTouch

Страница 1: ...5 YEAR LIMITED WARRANTY Innovation made simple SM INSTRUCTION MANUAL TSH 2 3 HEATING 2 COOLING HUMIDITY DUAL FUEL READY ...

Страница 2: ...CEIVER KIT Part No TOS Wireless Outdoor Temperature Transmitter and Receiver Kit Includes Transmitter Antenna Receiver Module 2 AA Batteries Accurately displays current Outdoor Temperature and enables Dual Fuel capability on the TrueTouch Thermostat ...

Страница 3: ...23 MENU SCREEN 24 DATE AND TIME SETTINGS 26 PROGRAM SETTINGS 27 ENERGY WATCH 28 SET SCREEN OPTIONS 29 VACATION MODE 30 FILTER MONITOR 31 ADVANCED SETTINGS FEATURES SETTINGS 32 ADVANCED SETTINGS SYSTEM CONFIGURATION 34 ADVANCED SETTINGS DUAL FUEL SWITCH 35 ADVANCED SETTINGS DIFFERENTIAL SETTINGS 36 ADVANCED SETTINGS TIMER FEATURE 37 ADVANCED SETTINGS HEAT PUMP 38 ADVANCED SETTINGS HUMIDITY SETTINGS...

Страница 4: ...moisture from the air DIFFERENTIAL Differential is defined as the difference between the cut in and cut out points as measured at the thermostat under specified operating conditions For example if the thermostat turns the heating equipment on at 70 degrees F and turns the heating equipment off at 74 degrees F then the differential is 4 degrees F HUMIDIFIER A device used to add moisture to a space ...

Страница 5: ...wall with the 3 supplied screws 8 Make the appropriate wire connections based on the specifications of the household HVAC unit s Please refer to Wiring Table to determine the appropriate wire connections 9 Place the thermostat on the backplate by firmly but gently from the top aligning the pins with the screw terminals 10 Turn on the electricity at the electrical service panel RC DH H C Y2 RH W2 O...

Страница 6: ... H C Y2 RH W2 OB W1 EH G Y1 COOL HEAT 24V FAN COMMON ONE STAGE COOL AND ONE STAGE HEAT RC DH H C Y2 RH W2 OB W1 EH G Y1 COOL WIRING DIAGRAMS 10 ONE STAGE COOL 24V FAN COOL COMMON RC DH H C Y2 RH W2 OB W1 EH G Y1 COOL 2 24V FAN COOL 1 COMMON TWO STAGE COOL RC DH H C Y2 RH W2 OB W1 EH G Y1 ...

Страница 7: ...W2 OB W1 EH G Y1 REVVALVE 24V FAN COMPRESSOR COMMON ONE STAGE HEAT PUMP RC DH H C Y2 RH W2 OB W1 EH G Y1 REVVALVE 24V FAN COMPRESSOR 1 COMMON TWO STAGE HEAT PUMP COMPRESSOR 2 RC DH H C Y2 RH W2 OB W1 EH G Y1 HEAT REVVALVE 24V FAN COMPRESSOR 1 COMMON TWO STAGE HEAT PUMP WITH AUX EMERGENCY HEAT COMPRESSOR 2 RC DH H C Y2 RH W2 OB W1 EH G Y1 ...

Страница 8: ...2 RH W2 OB W1 EH G Y1 HEAT TRANSFORMER ONE TRANSFORMER RC DH H C Y2 RH W2 OB W1 EH G Y1 HUMIDIFIER WITHOUT TRANSFORMER RC DH H C Y2 RH W2 OB W1 EH G Y1 24V HUMIDIFIER 2nd WIRE HUMIDIFIER 1st WIRE HEAT 2 HEAT 1 24V FAN COMMON TWO STAGE COOL AND TWO STAGE HEAT RC DH H C Y2 RH W2 OB W1 EH G Y1 COOL 2 COOL 1 ...

Страница 9: ...g thermostat operation mode button Select the Temperature Control Mode by toggling the temperature control mode button Select the Fan Operation Mode by toggling the fan oper ation mode button Select the Humidity Control mode by toggling the humidity control mode button 1 Access MENU SCREEN to enter into all thermostat features and settings Displays Installer Message to review important information...

Страница 10: ...nditioningtoregulateroomtemperature OFF Will not control temperature The thermostat will continue to display the current room temperature current room humidity and outdoor temperature THERMOSTAT OPERATION MODES 18 TrueTouch thermostat can operate in PROGRAM MODE or can HOLD a fixed temperature RUN PROGRAM Initiates the 7 day Programmable Temperature Control Program with 4 independent events per da...

Страница 11: ...on humidity must be controlled and air move ment must be generated As the exterior temperature drops the humidity level needs to decrease if condensation is to be controlled HUMIDITY AUTO TrueTouch thermostat will automatical ly adjusts the humidity set point based on the current indoor temperature and humidity as well as the current outdoor tem perature in order to maintain a maximum comfort leve...

Страница 12: ...e current relative humidity Your TrueTouch will both lower and regulate temperature to the cooling setpoint while monitoring and lowering the room humidity Since the De Humidify feature uses the COOL Function of your Air Conditioner or Heat Pump your TrueTouch thermostat will turn off the air conditioning if either the dehu midifier setpoint or temperature setpoint is reached which ever comes firs...

Страница 13: ...ess the ADVANCED SETTINGS hold the ADVANCED SET TINGS button for 5 seconds The therostat will continuously beep for 5 seconds to indi cate that you are in the process of entering this feature CAUTION Altering the system properties in the ADVANCED SETTINGS may affect the performance of the HVAC system and should be performed only by a qualified installer 25 MENU SCREEN 24 To access the MENU SCREEN ...

Страница 14: ...d FAN OPERATION MODE by fan operation mode button Enter the event START TIME with Hour Minute and AM PM buttons Choose desired TEMPERATURE SET POINT with and buttons Select the next event and repeat the steps described above Once finished select the next day of the week that you would like to program The thermostat will prompt you to copy the settings Repeat steps to program other days of the week...

Страница 15: ...o the normal display at 6 00AM OFF screen background is determined by REVERSE function CONTRAST Toggle the screen contrast settings button 1 11 to select the screen con trast that suits best your thermostat surroundings XCI recommends the setting of 7 28 ENERGY WATCH ENERGY WATCH feature provides a report on the energy con sumption and the dollar cost of operating your HVAC system for up to the la...

Страница 16: ... IMPORTANT HEAT or COOL must be selected from the CONTROL SCREEN before entering the Vacation Settings screen To begin select Vacation Mode ON Select the START Date Select the END Date Adjust the HEAT or COOL temperature setpoint the Vacation mode begins at 10 PM on the day of your departure and ends at Midnight on the day of your arrival When the Vacation mode is active the suitcase icon appears ...

Страница 17: ...FF dependent on your Time Zone FILTER Enter the air filter fan run time infor mation here The Filter Monitor feature uses this information to inform you when to change your air filter by displaying CHANGE FILTER icon on the HOME SCREEN ENERGY WATCH Enter the HVAC system consumption parameters rounded off to kW as well as your electrical energy cost kW and the ENERGY WATCH feature will display a re...

Страница 18: ... take over HP Cut ON or OFF Cut Temperature Temperature in Celsius 5 c to 25 c Temperature in Fahrenheit 13 F to 41 F ADVANCED SETTINGS SYSTEM CONFIGURATION 34 IMPORTANT By inadvertently modifying system configuration settings you may seriously degrade HVAC system performance Choose system heating and cooling equipment remember all you need to do is toggle the appropriate button until the correct ...

Страница 19: ...eTouch TSH 2 allows you to control up to 3 Stages of Heating and 2 Stages of Cooling dependent on the type of system you have configured 1ST STAGE DIFFERENTIAL Set temperature difference between temperature set point and actual temperature reading before 1st stage heating or cooling is initiated 2ND STAGE DIFFERENTIAL Set temperature difference between 1st stage initiation and 2nd stage heating or...

Страница 20: ...N fan runs when there is an independent demand to dehumidify OFF fan only runs when there is a demand to dehumidify while cooling DH REVERSE ON DH relay is normally closed when relative humidity is above DH set point OFF DH relay is normally open when relative humidity is above DH set point DH CONTROL COMPRESSOR ON Thermostat will turn off the air conditioning if either the dehumidify set point or...

Страница 21: ...nnect the DH terminal to a variable speed fan control set DH REVERSE to control the fan so that low speed is activated to de humidify This method provides max imum comfort while maintaining the temperature in cooling mode ADVANCED SETTINGS HUMIDITY SETTINGS 40 Operating Tips HUMIDIFICATION FAN should be set to ON when running steam or mist humidifiers HUMIDIFICATION FAN should be set to OFF when r...

Страница 22: ...ADVANCED SETTINGS CALIBRATION 42 Calibration of Temperature or Relative Humidity The TrueTouch Thermostat is rated for an accuracy of 1 F 0 5 C with temperature and 5 for Relative Humidity If you have determined due to drafts sunlight or other environmental factors that your ther mostat requires calibration follow this easy guide Common cause of offset are lack of air circulation drafts or skyligh...

Страница 23: ...re another possible solution is to connect one 250 ohm 10 watt resistor in the HVAC room for cooling problems between C and W or in the case of heating problem between C and Y1 I forgot my PIN and cannot unlock the thermostat Remove the cover plate press the reset button located in the bottom right corner as soon as the message touch to reset password appears touch the screen your PIN will be eras...

Страница 24: ...empts to open repair or modify the product or any other cause beyond the range of intended use 3 damage caused by accident fire power changes other hazard or Acts of God or 4 use of the product with any device if such device causes the problem EXCLUSIVE REMEDIES Should a covered defect occur during the warranty period and Customer notifies XCI Controls L P Customer s sole and exclusive remedy will...

Страница 25: ...CAUSE UNDESIRED OPERATION TECHNICAL SUPPORT 1 866 XCI CTRL 1 866 924 2875 PHYSICAL DIMENSIONS Case 5 75 x 4 75 x 1 25 Screen 4 1875 ELECTRICAL RATING 24 volt AC DC Class 2 maximum 4 amps ACCURACY RATING Temperature Accuracy 1 F 0 5 C Humidity Accuracy 5 RH See Warranty Statement for Details and Limitations TSH 2 MANUAL PRINTED IN CHINA www xcicontrols com PATENTS 7 185 825 7 156 318 7 145 110 7 05...

Отзывы: