18
Make sure that the equipment is depressurized,
cooled down to room temperature and free from
fluid.
To reduce the pressure through the bore in the
cover slowly loosen the sealing plug by two
turns (10).
Remove the cap nut (1).
Remove the outer gasket (26) from the
adjustment screw.
Remove the hexagon nut (25).
Remove the inner gasket (26) from the
adjustment screw.
Screw in the adjustment screw (9) until it hits
the stop.
Remove the sealing plug (10).
Take the gasket (27) out of the body.
Insert a screwdriver through the bore for the
sealing plug and push down the lift plate (21).
Loosen the adjustment screw (9) until the lift
plate starts to lift.
To change the minimum flowrate loosen the
adjustment screw by the number of turns
specified in the chart.