Section 5 - Troubleshooting Flow Charts
2000 PSI
less than 2000 PSI
CHART 16
Continued from the
previous page.
Re-install all hydraulic
lines in the original
configuration then
remove and cap the
function up pressure line
port (R1) on the manifold
OR cap the hose at the
point the hose connects
to the engine side
cylinder on the. Hold
function switch up and
check pressure.
Repair both secondary
function cylinders.
One of the previous tests
involving the pump or
manifold components
was possibly overlooked
or diagnosed incorrectly.
Recheck and/or consult
Geinie Industries service
department.