Part No. 29487
Genie Z-45/22
7 - 39
Service Manual - First Edition
Section 7 - Repair Procedures
continuity (zero
Ω)
13 to 17
Ω
no continuity
(infinite
Ω
)
no continuity
(infinite
Ω
)
9-2
Power Relay
Electrocution hazard. Contact with
hot or live circuits may result in
death or serious injury. Remove
all rings, watches and other
jewelry.
How to Test the Power Relay
Electrocution hazard. Disconnect
the ground cable from the battery
before performing this procedure.
1 Connect the leads from an ohmmeter to each
terminal combination and check for continuity.
Test
Desired result
2 small posts
2 large posts
Any small post to
any large post
2 Connect 12V DC to one of the small posts and
ground to the other small post, then test the
following terminal combination.
Test
Desired result
2 large posts
RELAY PANEL
a
b
a
b
a
high amp power contact terminals
(large posts)
b
solenoid activate coil terminals
(small posts)
Содержание Z-45/22
Страница 1: ...Technical Publications First Edition Part No 29487 Service Manual Z 45 22 ...
Страница 65: ...Part No 29487 Genie Z 45 22 4 39 Service Manual First Edition Section 4 Scheduled Maintenance Procedures ...
Страница 66: ...4 40 Genie Z 45 22 Part No 29487 Service Manual First Edition Section 4 Scheduled Maintenance Procedures ...
Страница 121: ...6 3 ...
Страница 122: ......
Страница 123: ...6 5 ...
Страница 124: ...6 6 ...
Страница 125: ...6 7 ...
Страница 126: ...6 8 ...
Страница 127: ......
Страница 128: ...6 10 ...
Страница 129: ...6 11 ...
Страница 130: ...6 12 ...
Страница 132: ...Z45 22 Hyd Index ...
Страница 133: ...Z45 22 Hyd Index ...
Страница 134: ...Z45 22 Hyd Index ...
Страница 135: ...Z45 22 Hyd Index ...
Страница 136: ...Z45 22 Hyd Index ...
Страница 137: ...Z45 22 Hyd Index ...