5 - 50
Genie Z-45/22
Part No. 29487
Service Manual - First Edition
Section 5 - Troubleshooting Flow Charts
voltage readings are different
Repair or replace the
drive controller.
Drive Forward
Or Reverse
Function
Inoperative
Be sure all other
functions operate
normally including
drive in opposite
direction of
malfunction.
Disconnect the EDC wire
connector from the drive
pump , start engine,
move the drive controller
to full forward position
and note the voltage
across terminals TB27
and TB26. Reverse the
volt meter leads and
move the drive controller
to full reverse position
and note the voltage.
voltage readings are the same
no improvement
Defective Sundstrand
drive pump, contact
Sundstrand authorized
repair facility
Adjust the drive pump
null (neutral). See
Sundstrand Series 40
Service Manual.
symptoms improve
Check all drive speeds
and monitor for recurring
symptoms. Possible
contamination in
hydraulic system.
Chart 34
Содержание Z-45/22
Страница 1: ...Technical Publications First Edition Part No 29487 Service Manual Z 45 22 ...
Страница 65: ...Part No 29487 Genie Z 45 22 4 39 Service Manual First Edition Section 4 Scheduled Maintenance Procedures ...
Страница 66: ...4 40 Genie Z 45 22 Part No 29487 Service Manual First Edition Section 4 Scheduled Maintenance Procedures ...
Страница 121: ...6 3 ...
Страница 122: ......
Страница 123: ...6 5 ...
Страница 124: ...6 6 ...
Страница 125: ...6 7 ...
Страница 126: ...6 8 ...
Страница 127: ......
Страница 128: ...6 10 ...
Страница 129: ...6 11 ...
Страница 130: ...6 12 ...
Страница 132: ...Z45 22 Hyd Index ...
Страница 133: ...Z45 22 Hyd Index ...
Страница 134: ...Z45 22 Hyd Index ...
Страница 135: ...Z45 22 Hyd Index ...
Страница 136: ...Z45 22 Hyd Index ...
Страница 137: ...Z45 22 Hyd Index ...