Part No. 29487
Genie Z-45/22
4 - 15
Service Manual - First Edition
Section 4 - Scheduled Maintenance Procedures
B-10
Check the Engine Choke -
Gasoline/LPG Models
Automatic Choke
The machine is equipped with an
automatic choke if a choke switch
can't be found near the start
switch. The automatic choke does
not need to be inspected or
adjusted unless the following
conditions exist:
· The machine does not start
easily in cold temperatures.
· The engine does not run
smoothly after a cold start.
See 7-4,
Choke Adjustments.
Manual Choke
A properly functioning choke is essential to good
engine performance. An improperly functioning
choke will result in difficulty with engine starting.
1 Check the choke linkage connections.
a
linkage
b
carburetor
c
linkage lock nuts
d
choke solenoid
2 Turn the key switch to ground control and then
pull out the ground control Emergency Stop
button to the
on position.
3 While operating the choke switch, inspect the
choke solenoid.
Result: The choke solenoid should be fully
retracted when the choke switch is activated.
4 Turn the key switch to platform control.
5 Pull out the platform control Emergency Stop
button to the
on position and then operate the
choke switch and listen for choke solenoid
operation.
a
d
c
b
B-11
Check the Glow Plugs
- Diesel Models
Maintaining the glow plugs in good condition is
essential to good engine performance and service
life. Improperly functioning glow plugs will cause
the engine to perform poorly and may result in
component damage.
Perform this procedure with the
engine turned off.
1 Connect an ohmmeter between the far left
glow plug and machine ground.
Result: The resistance should be approximately
0.4
Ω.
2 If the ohm reading is different than 0.4
Ω
,
remove each wire from the four individual glow
plugs. Then, one glow plug at a time, check the
resistance between the glow plug and machine
ground.
Result: The resistance should be approximately
1.6
Ω
for each individual glow plug.
3 Turn the machine on, but do not start the
engine.
4 Connect a volt meter to the number four glow
plug and machine ground.
5 Hold the glow plug switch in the
on position.
Result: The volt meter should read 12 volts.
TABLE
B
PROCEDURES
Содержание Z-45/22
Страница 1: ...Technical Publications First Edition Part No 29487 Service Manual Z 45 22 ...
Страница 65: ...Part No 29487 Genie Z 45 22 4 39 Service Manual First Edition Section 4 Scheduled Maintenance Procedures ...
Страница 66: ...4 40 Genie Z 45 22 Part No 29487 Service Manual First Edition Section 4 Scheduled Maintenance Procedures ...
Страница 121: ...6 3 ...
Страница 122: ......
Страница 123: ...6 5 ...
Страница 124: ...6 6 ...
Страница 125: ...6 7 ...
Страница 126: ...6 8 ...
Страница 127: ......
Страница 128: ...6 10 ...
Страница 129: ...6 11 ...
Страница 130: ...6 12 ...
Страница 132: ...Z45 22 Hyd Index ...
Страница 133: ...Z45 22 Hyd Index ...
Страница 134: ...Z45 22 Hyd Index ...
Страница 135: ...Z45 22 Hyd Index ...
Страница 136: ...Z45 22 Hyd Index ...
Страница 137: ...Z45 22 Hyd Index ...