5 - 54
Genie Z-45/22
Part No. 29487
Service Manual - First Edition
Section 5 - Troubleshooting Flow Charts
no continuity
full continuity
full continuity
no continuity
Machine Will
Not Drive At
Full Speed
Be sure all other
functions operate
normally.
With boom fully stowed,
check TB37 for
continuity to ground.
With boom fully stowed,
check horsepower limiter
board terminal 6 for
continuity to ground.
Repair or replace drive
limit switch.
Orange wire shorted to
ground, repair orange
wire circuit from TB37 to
horsepower limiter
board.
Re-adjust horsepower
limiter board. See Repair
section.
Chart 37