80
•
Operational Reference
Genie Nano-CL Series™
File Access Control Feature Descriptions
The Device Version number represents the camera software functional group, not a firmware
revision number. As Genie Nano capabilities evolve the device version tag will increase, therefore
identifying the supported function package. New features for a major device version release will be
indicated by
green text
for easy identification.
Display Name
Feature & Values
Description
Device
Version
& View
File Selector
FileSelector
Selects the file to access. The file types which are
accessible are device-dependent.
1.00
Guru
Firmware
Firmware1 Upload new firmware to the camera which will
execute on the next camera reboot cycle. Select
the DeviceReset feature after the upload
completes.
Factory Defective Pixel Map
BadPixelCoordinate0 Select the Factory Defective Pixel Map.
User Defective Pixel Map
BadPixelCoordinate1 Select the User
file as
defined in Advanced Processing.
Color Correction Coefficients
ColorCorrection Select the color correction coefficients.
Factory Flat Line coefficients 1
FlatFieldCoefficients01 Select factory Flat Line coefficients 1. These are
the factory values used when the camera
fastReadoutMode is Off and sensor Gain is 1.0.
Factory Flat Line coefficients 2
FlatFieldCoefficients02 Select factory Flat Line coefficients 2. These are
the factory values used when the camera
fastReadoutMode is Off and sensor Gain is 1.26.
Factory Flat Line coefficients 3
FlatFieldCoefficients03 Select factory Flat Line coefficients 3. These are
the factory values used when the camera
fastReadoutMode is Off and sensor Gain is 1.87.
Factory Flat Line coefficients 4
FlatFieldCoefficients04 Select factory Flat Line coefficients 4. These are
the factory values used when the camera
fastReadoutMode is Off and sensor Gain is 3.17.
Factory Flat Line coefficients 5
FlatFieldCoefficients05 Select factory Flat Line coefficients 5. These are
the factory values used when the camera
fastReadoutMode is Active and sensor Gain is 1.0.
Factory Flat Line coefficients 6
FlatFieldCoefficients06 Select factory Flat Line coefficients 6. These are
the factory values used when the camera
fastReadoutMode is Active and sensor Gain is
1.26.
Factory Flat Line coefficients 7
FlatFieldCoefficients07 Select factory Flat Line coefficients7. These are
the factory values used when the camera
fastReadoutMode is Active and sensor Gain is
1.87.
Factory Flat Line coefficients 8
FlatFieldCoefficients08 Select factory Flat Line coefficients 8. These are
the factory values used when the camera
fastReadoutMode is Active and sensor Gain is
3.17.
User Flat Line coefficients 1
FlatFieldCoefficients1 Select user Flat Line coefficients1. These are the
coefficient values used when the sensor analog
Gain is 1.0.
User Flat Line coefficients 2
FlatFieldCoefficients2 Select user Flat Line coefficients2. These are the
coefficient values used when the sensor Gain is
1.26.
User Flat Line coefficients 3
FlatFieldCoefficients3 Select user Flat Line coefficients3. These are the
coefficient values used when the sensor Gain is
1.87.
User Flat Line coefficients 4
FlatFieldCoefficients4 Select user Flat Line coefficients4. These are the
coefficient values used when the sensor Gain is
3.17.
Lens Shading Correction 1
LensShadingCorrection1 Lens Shading coefficients set 1
Содержание Nano-CL C2450
Страница 94: ...92 Technical Specifications Genie Nano CL Series EC FCC Declarations of Conformity...
Страница 104: ...102 Additional Reference Information Genie Nano CL Series Cable Assembly G3 AIOC BLUNT1M...
Страница 105: ...Genie Nano CL Series Additional Reference Information 103 Cable Assembly G3 AIOC BLUNT2M...
Страница 106: ...104 Additional Reference Information Genie Nano CL Series...
Страница 107: ...Genie Nano CL Series Additional Reference Information 105 Cable Assembly G3 AIOC BRKOUT2M...
Страница 108: ...106 Additional Reference Information Genie Nano CL Series...
Страница 109: ...Genie Nano CL Series Additional Reference Information 107 Nano Generic Power Supply with no I O...
Страница 111: ...Genie Nano CL Series Additional Reference Information 109 Cable Assembly Right Angle I O to Euro Block...