Genie Nano-CL Series™
Operational Reference
•
49
•
TriggerOverlap=ReadOut
•
Trigger is accepted at the beginning of the frame Readout. The “End of Exposure to Start of
Readout” time is sensor dependent.
Diagram Conditions:
•
TriggerMode=On
•
ExposureMode=Timed
•
TriggerActivation=RisingEdge
•
TriggerDelay=0
•
TriggerSelector=FrameStart
•
ExposureAlignment=Synchronous
Trigger Input
Trigger Exclusion Period
Exposure 1
Readout 1
Frame 1 Active period
Exposure 2
Readout 2
Frame 2 Active period
Frame Exposure
Frame Readout
TriggerOverlap=Readout
Trigger Exclusion Period
End of Exposure
to Start of Readout
End of Exposure
to Start of Readout
Timing specific to OnSemi models
•
Trigger to Exposure start has a delay which includes the sensor readout time plus a
minimum of 62µs. An exposure always starts after the readout of the previous frame.
•
Trigger Delay Times (min. with normal ROT):
•
Nano-CL Specifications: M5100, C5100, M4090, C4090
Содержание Nano-CL C2450
Страница 94: ...92 Technical Specifications Genie Nano CL Series EC FCC Declarations of Conformity...
Страница 104: ...102 Additional Reference Information Genie Nano CL Series Cable Assembly G3 AIOC BLUNT1M...
Страница 105: ...Genie Nano CL Series Additional Reference Information 103 Cable Assembly G3 AIOC BLUNT2M...
Страница 106: ...104 Additional Reference Information Genie Nano CL Series...
Страница 107: ...Genie Nano CL Series Additional Reference Information 105 Cable Assembly G3 AIOC BRKOUT2M...
Страница 108: ...106 Additional Reference Information Genie Nano CL Series...
Страница 109: ...Genie Nano CL Series Additional Reference Information 107 Nano Generic Power Supply with no I O...
Страница 111: ...Genie Nano CL Series Additional Reference Information 109 Cable Assembly Right Angle I O to Euro Block...