Genie Nano-CL Series™
Operational Reference
•
51
•
TriggerOverlap= Readout and ExposureMode=TriggerWidth
•
This special condition describes the case of a short TriggerWidth exposure relative to the
readout period. If the next Trigger input signal occurs during the previous frame readout,
attempting to stop the frame active period before the current readout is completed, the camera
will continue the second exposure until the previous readout is completed. In this condition the
actual exposure time is longer than the trigger input width.
Diagram Conditions (OnSemi Sensors):
•
TriggerMode=On
•
ExposureMode=TriggerWidth
•
TriggerActivation=RisingEdge
•
TriggerDelay=0
•
TriggerSelector=FrameStart
•
ExposureAlignment=Synchronous
Trigger Input
Exposure 1
Readout 1
Frame 1 Active period
Exposure 2
Readout 2
Frame 2 Active period
Frame Exposure
Frame Readout
OnSemi Sensor TriggerOverlap= Readout
and
ExposureMode=TriggerWidth
Exposure 2 delayed so that it ends when Readout 1 ends
Содержание Nano-CL C2450
Страница 94: ...92 Technical Specifications Genie Nano CL Series EC FCC Declarations of Conformity...
Страница 104: ...102 Additional Reference Information Genie Nano CL Series Cable Assembly G3 AIOC BLUNT1M...
Страница 105: ...Genie Nano CL Series Additional Reference Information 103 Cable Assembly G3 AIOC BLUNT2M...
Страница 106: ...104 Additional Reference Information Genie Nano CL Series...
Страница 107: ...Genie Nano CL Series Additional Reference Information 105 Cable Assembly G3 AIOC BRKOUT2M...
Страница 108: ...106 Additional Reference Information Genie Nano CL Series...
Страница 109: ...Genie Nano CL Series Additional Reference Information 107 Nano Generic Power Supply with no I O...
Страница 111: ...Genie Nano CL Series Additional Reference Information 109 Cable Assembly Right Angle I O to Euro Block...