Genie Nano-CL Series™
Operational Reference
•
47
Pin7=Signal – Pin3=Gnd
Pin7Signal_Pin3Gnd Pin 7 is the Input Signal and Pin 3 is the common
input Ground on the I/O connector.
Pin6=Signal – Pin4=Pwr
Pin6Signal_Pin4Pwr Pin 6 is the Output Signal and Pin 4 is the common
output Power on the device connector.
Pin8=Signal – Pin4=Pwr
Pin8Signal_Pin4Pwr Pin 8 is the Output2 Signal and Pin 4 is the
common output Power on the device connector.
I/O Module Block Diagram
Line Selector =
Line C1 or C2
Physical
Line
Input
inverter
LineStatus
Trigger
Line
Activation
Trigger Signal
Timer
TimerEnd Event
CounterEnd Event
Software Trigger
Cmd
Input
Timer and Counter Module
Counter
Line
Debouncer
Event Driven
Trigger
Source
Trigger Module
Line
Detection
Level
Trigger Mode Details
Nano-CL image exposures are initiated by an event. The trigger event is either the camera’s
programmable internal clock used in free running mode, an external input to the controlling frame
grabber used for synchronizing exposures to external triggers, or a programmed function call
message by the controlling computer. These triggering modes are described below.
•
Free running (Trigger Mode=Off): The Nano free-running mode has programmable internal
timers for frame rate and exposure period. Frame rate minimums, maximums, and increments
supported are sensor specific. Maximum frame rates are dependent on the required exposure.
•
Trigger Source (Trigger Mode=On): Exposures are controlled by an external trigger signal
where the specific input line is selected by the Trigger Source feature.
Trigger Source Types (Trigger Mode=On)
•
Trigger Source=CC1: The Camera Link CC1 line (controlled by the frame grabber) is used as
the external trigger control.
•
Trigger Source=Software: An exposure trigger is sent as a software command. Software
triggers cannot be considered time accurate due to computer latency and sequential command
jitter. But a software trigger is more responsive than calling a single-frame acquisition since the
latter must validate the acquisition parameters and modify on-board buffer allocation if the
buffer size has changed since the last acquisition.
•
Trigger Source=Timer1End Event: The Timer1 End Event is used as the internal trigger
source. Refer to
for information on those features.
•
Trigger Source=Counter1End Event: The Counter1 End Event is used as the internal trigger
source.
Содержание Nano-CL C2450
Страница 94: ...92 Technical Specifications Genie Nano CL Series EC FCC Declarations of Conformity...
Страница 104: ...102 Additional Reference Information Genie Nano CL Series Cable Assembly G3 AIOC BLUNT1M...
Страница 105: ...Genie Nano CL Series Additional Reference Information 103 Cable Assembly G3 AIOC BLUNT2M...
Страница 106: ...104 Additional Reference Information Genie Nano CL Series...
Страница 107: ...Genie Nano CL Series Additional Reference Information 105 Cable Assembly G3 AIOC BRKOUT2M...
Страница 108: ...106 Additional Reference Information Genie Nano CL Series...
Страница 109: ...Genie Nano CL Series Additional Reference Information 107 Nano Generic Power Supply with no I O...
Страница 111: ...Genie Nano CL Series Additional Reference Information 109 Cable Assembly Right Angle I O to Euro Block...