background image

R

PROGRAMMING

INSTRUCTIONS

HARDWIRE

WIRELESS

G E M - P 3 2 0 0

CONTROL PANEL/COMMUNICATOR

WI818D 8/00

© Napco 2000

Quick Start:

1.  Refer to the wiring diagram, connect the keypad(s), siren, aux. power, aux. output, remote bus, earth ground, zone and telephone 

wiring. NOTE: See Installation Instructions (WI817).

2.  Connect AC power first and then the battery.

3.  Configure the keypad (see page 63).

4.  Access the Easy Menu Driven (Dealer Program) Mode:

Press 

EEEEEE A

       

 Press  

g

Until “

ACTIVATE PROGRAM Y/N

” (GEM-RP1CAe2), “

TURNON PROG Y/N

” (GEM-RP2ASe2) or

                               

“17”

 

(GEM-RP3DGTL) appears on the keypad display.

        

Press  

F

To Enter Dealer Program Mode (see page 6).

Master Security Code

(on microshield)

R

COMPUTERIZED SECURITY SYSTEM

ARMED

STATUS

SYSTEM ARMED
01/01/97    12:00AM

1 2
4

3

5 6

7 8 9 0

A
B
C

D

E
F
G

NEXT/YES

PRIOR/NO

AREA

GEMINI

ENT A1

48

INTERIOR

BYPASS

FIRE/TBL

SYS TBL

CHIME

GEM-RP2ASe2

R

COMPUTERIZED SECURITY SYSTEM

ARMED

STATUS

SYSTEM ARMED
01/01/97    12:00AM

1 2
4

3

5 6

7 8 9 0

A
B
C

D

E
F
G

NEXT/YES

PRIOR/NO

AREA

GEMINI

READY

AC ON

READY

AC ON

GEM-RP1CAe2

R

COMPUTERIZED SECURITY SYSTEM

GEMINI

ARM

ED

STAT

US

SYSTEM ARMED
01/01/97    12:00AM

1 2
4

3

5 6

7 8 9 0

A
B
C

D

E
F
G

NEXT/YES

PRIOR/NO

AREA

SYSTEM ARMED

01/01/00   12:00 AM

GEM-RP3DGTL

Содержание Gemini GEM-P3200

Страница 1: ... N GEM RP2ASe2 or 17 GEM RP3DGTL appears on the keypad display Press F To Enter Dealer Program Mode see page 6 Master Security Code on microshield R COMPUTERIZED SECURITY SYSTEM ARMED STATUS SYSTEM ARMED 01 01 97 12 00AM 1 2 4 3 5 6 7 8 9 0 A B C D E F G NEXT YES PRIOR NO AREA GEMINI ENT A1 48 INTERIOR BYPASS FIRE TBL SYS TBL CHIME GEM RP2ASe2 R COMPUTERIZED SECURITY SYSTEM ARMED STATUS SYSTEM ARM...

Страница 2: ...lure Modes New Relay Event Area Disarmed PCD3000 programmable only Programmable DST start date PCD3000 programmable only 20 Digit Dialing Prefix NOTE Typically any version GEM P3200 control panel could be upgraded to the latest firmware by replacing the EPROM with a newer version This is no longer the case The Firmware Version 20 EPROM must only be used in a Version 18 or greater PCBoard Do NOT at...

Страница 3: ...0 36 CS Receiver Opt Addr 0520 0521 0525 0526 0550 0551 0575 0576 37 CS Receiver Tel Numbers Addr 0527 0546 0552 0571 0577 0596 38 Download Callback Options Addr 4089 0600 0619 0625 0647 1022 1023 38 CS Subscriber ID Numbers Addr 0650 0857 39 CS Reporting Codes Addr 0860 0869 40 CS Reporting Codes Addr 0870 0904 41 CS Area System Reporting Opt Addr 1024 1027 41 CS Zone Reporting Codes Addr 0910 09...

Страница 4: ...y location This mode is accessed from the Easy Menu Driven Program Mode by pressing the C button at any time User Program Mode Keypad programming The User Program Mode is intended for authorized users and is limited to keypad programming of User Codes Zone Descriptions Time and Date DOWNLOADING FROM A COMPUTER The control panel program may be downloaded from the computer by either of the following...

Страница 5: ...ay alter it as necessary in the Direct Address Program Mode KEYPAD 1 For ease of programming it is recommended that a GEM RP1CAe2 Version 6 be used as Keypad 1 Regardless of which keypad is selected all new keypads are configured as Keypad 1 out of the box NEW PANELS The custom default program may be created for new panels only Once the panel has been programmed by any means the number of areas nu...

Страница 6: ... or wireless Valid entries are from 01 to 48 Directly enter each zone number including leading zeros and press Jto save and then repeat for any additional zone s Press NEXT E button to proceed NOTE If you are programming a 2 Area system enter the zone number of zones required for Areas 1 2 All fire zones are common to areas 1 and 2 The Direct Address Program Mode can then be used to customize them...

Страница 7: ...be installed in Area 2 Valid entries are from 01 to 07 Central Station Receiver 1 Telephone Number Using number buttons enter telephone number of up to 16 digits including prefix letters if necessary for receiver 1 Use number buttons 1 through 9 for digits 1 9 press the G 0 button for a zero and G 1 through G 5 for letters B F respectively NOTE Pre Dial Delay D Dial Tone Detection E Pressing the 0...

Страница 8: ...number buttons 1 through 9 NOTE Press the 0 button for a zero and press the G 0 buttons for a blank space Press G 1 through G 4 for letters B E respectively Press Jto save Press NEXT E button to proceed DATA ENTRY CS RECEIVER 1 FORMAT blank Ademco Slow Silent Knight Slow 1 Sescoa Vertex DCI Franklin Fast 2 Radionics Fast 3 Silent Knight Fast 4 Radionics DCI Franklin Slow 5 Universal High Speed 8 R...

Страница 9: ...s data in the left digit Enter the level data with arming options if any added in the right digit Note For entries greater than 9 press the G1 buttons through the G5 buttons for B through F respectively For Keypad Access Control press the A button once again to program applicable keypads Refer to the tables below use the number buttons to enter the data for Keypad 1 4 in the right digit and the da...

Страница 10: ...de with appropriate user option Requires Dealer Code Related User Options Ambush Code Address 0495 Panel Access Code Address 0490 Dealer Security Code Address 0500 Enable User Code by Area Address 2500 2547 USER OPTIONS OPTIONS EXPLANATION Disabled User Code not active in this area Blocked View Allows User Code to block another code from being viewed by another user An unblocked code cannot view a...

Страница 11: ...hree points to Zones 11 13 respectively 1 Enter the Enroll mode as described in step 2 above 2 Enter Zone 11 3 Open the loops of points 1 2 and 3 4 Install the transmitter battery The keypad will beep 3 times to indicate that three points have been programmed Transmitter 410078 1 point 1 will be mapped to Zone 11 Transmitter 410078 1 point 2 will be mapped to Zone 12 Transmitter 410078 1 point 3 w...

Страница 12: ...he key fob zone number with description location To assign a key fob to a zone program the key fob as you would a transmitter entering the key fob s ID code check sum and point number at the appropriate zone The Quick Method is not allowed The zone may be hardwired to a sensor as well as assigned to a key fob either one will activate the zone alarm output NOTE If assigning a key fob to a zone the ...

Страница 13: ...t Entry E N T E R T I M E 1 2 0 5 A Direct Entry DEALER CODE Direct Entry DEALER CODE RE ENTER EXIT DEALER PROGRAM MODE This completes the custom default program Press the C button to enter the Direct Address Program Mode for further programming or press the C button once again to end all programming and resume normal keypad operation Clear Dealer Program Erases Dealer Program This erases the deal...

Страница 14: ...ptions see Zone and Keypad Options in Direct Address Programming Fire Zones Appears for New Panel Only Enter the zone number of any Fire Zones both 2 wire 4 wire or wireless Valid entries are from 01 to 48 Directly enter each zone number including leading zeros and press Jto save and then repeat for any additional zone s Press NEXT E button to proceed NOTE If you are programming a 2 Area system en...

Страница 15: ...ctly enter each zone number including leading zeros Use number buttons 1 through 9 NOTE Press the 0 button for a zero Press Jto save and then repeat for any additional zone s Press NEXT E button to proceed NOTE All Interior zones will also be automatically programmed as Exit Entry Follower zones If you are programming a 2 Area system enter all the zones required for Areas 1 2 Number of Keypads in ...

Страница 16: ... the G0 button for a zero and press 0 button for a blank space Press G 1 through G 4 for letters B E respectively Press Jto save Press NEXT E button to proceed NOTE Central Station Receiver 2 and 3 Account Numbers can only be entered in Direct Address Programming See CS Reporting Options Central Station Receiver 1 Format Press the A button to scroll screens From the table below enter the central s...

Страница 17: ...le data entries Enter the options data in the left digit Enter the level data with arming options if any added in the right digit Note For entries greater than 9 press the G1 buttons through the G5 buttons for B through F respectively For Keypad Access Control press the A button once again to program applicable keypads Refer to the tables shown use the number buttons to enter the data for Keypad 1...

Страница 18: ... Code Related User Options Ambush Code Address 0495 Panel Access Code Address 0490 Dealer Security Code Address 0500 Enable User Code by Area Address 2500 2547 USER OPTIONS OPTIONS EXPLANATION Disabled User Code not active in this area Blocked View Allows User Code to block another code from being viewed by another user An unblocked code cannot view a blocked code but a blocked code can view all c...

Страница 19: ... number 410078 1 Map the first three points to Zones 11 13 respectively 1 Enter the Enroll mode as described in step 2 above 2 Enter Zone 11 3 Open the loops of points 1 2 and 3 4 Install the transmitter battery The keypad will beep 3 times to indicate that three points have been programmed Transmitter 410078 1 point 1 will be mapped to Zone 11 Transmitter 410078 1 point 2 will be mapped to Zone 1...

Страница 20: ...on point 2 A1 point 3 A2 point 4 Up to 48 key fobs using 1 button or 24 key fobs using 2 buttons or 14 key fobs using all 4 buttons or any combination up to a maximum of 48 controlled zones can be assigned providing multiple wireless panic buttons on a system each reporting to the Central Station or a pager and or annunciating on a keypad the key fob zone number with description location To assign...

Страница 21: ...ess Jto save Press NEXT E button to proceed NOTE The Dealer Code can be two or more digits up to 6 digits CLEAR PROGRAM Should it be necessary to create a new custom default program a from the Dealer Program Mode press the C button to enter the Address Program Mode b access Location 4091 Clear Program or 4093 Cold Start c press Jand then d press the C button to exit the Dealer Program Mode A Syste...

Страница 22: ...ding zeros and press Jto save and then repeat for any additional zone s Press NEXT E button to proceed NOTE If you are programming a 2 Area system enter the zone number of zones required for Areas 1 2 All fire zones are common to areas 1 and 2 The Direct Address Program Mode can then be used to customize them as needed See Zone Options 2 Wire Fire Zones Appears for New Panel Only Enter the zone nu...

Страница 23: ... number of keypads including leading zeros Use number buttons 1 through 9 NOTE Press the 0 button for a zero Press Jto save Press NEXT E button to proceed Number of Keypads in Area 2 Directly enter the total number of Keypads to be installed in Area 2 Valid entries are from 01 to 07 Directly enter the number of keypads including leading zeros Use number buttons 1 through 9 NOTE Press the 0 button ...

Страница 24: ... buttons for a blank space Press G 1 through G 4 for letters B E respectively Press Jto save Press NEXT E button to proceed DATA ENTRY CS RECEIVER 1 FORMAT blank Ademco Slow Silent Knight Slow 1 Sescoa Vertex DCI Franklin Fast 2 Radionics Fast 3 Silent Knight Fast 4 Radionics DCI Franklin Slow 5 Universal High Speed 8 Radionics BFSK DATA ENTRY CS RECEIVER 1 FORMAT 9 FBI 4 3 1 0 Radionics Modem 2 B...

Страница 25: ...evel data with arming options if any added in the right digit Note For entries greater than 9 press the G1 buttons through the G5 buttons for B through F respectively For Keypad Access Control press the A button once again to program applicable keypads Refer to the tables below use the number buttons to enter the data for Keypad 1 4 in the right digit and the data for Keypad 5 7 data in the left d...

Страница 26: ... with appropriate user option Requires Dealer Code Related User Options Ambush Code Address 0495 Panel Access Code Address 0490 Dealer Security Code Address 0500 Enable User Code by Area Address 2500 2547 USER OPTIONS OPTIONS EXPLANATION Disabled User Code not active in this area Blocked View Allows User Code to block another code from being viewed by another user An unblocked code cannot view a b...

Страница 27: ...1 Map the first three points to Zones 11 13 respectively 1 Enter the Enroll mode as described in step 2 above 2 Enter Zone 11 3 Open the loops of points 1 2 and 3 4 Install the transmitter battery The keypad will beep 3 times to indicate that three points have been programmed Transmitter 410078 1 point 1 will be mapped to Zone 11 Transmitter 410078 1 point 2 will be mapped to Zone 12 Transmitter 4...

Страница 28: ...transmitter entering the key fob s ID code check sum and point number at the appropriate zone The Quick Method is not allowed The zone may be hardwired to a sensor as well as assigned to a key fob either one will activate the zone alarm output NOTE If assigning a key fob to a zone the ON OFF buttons on the key fob will no longer arm disarm the system The key fob is converted to a panic only device...

Страница 29: ...e all the options It consists of multiple address locations up to 4093 with two data entry locations each left and right as shown in the adjacent diagram ACCESSING DIRECT ADDRESS PROGRAM MODE DATA ENTRY LOCATIONS LEFT DIGIT RIGHT DIGIT 3 C ADDRESS LOCATIONS 0000 0000 TO 4093 HEXADECIMAL DATA BLANK No Options 1 to 9 Entries 1 to 9 0 Entry of 10 B to F Entries 11 to 15 1 Press EEEEEE A 2 Press g Unt...

Страница 30: ...E C O N D S E X I T T I M E D L Y 1 2 1 2 ADDRESS LOCATION 1 2 DATA ENTRY LOCATION Left and Right Digits Accessing Direct Address Program Mode Direct Entry 3P INTERIOR BYPASS FIRE TBL SYS TBL CHIME 3CINTERIOR BYPASS SYS TBL CHIME FIRE TBL 1 2 GEM RP3DGTL Keypad Press the A followed by 4 digit address location NOTE The address location will flash rapidly and then disappear with the corresponding da...

Страница 31: ...ton 2 Enter the 4 digit Address location directly using number buttons 0 9 3 Enter the 2 digit data directly using number buttons 0 9 4 Press the Jbutton to save To exit press the C button NOTE A G 0 B G 1 C G 2 D G 3 E G 4 F G 5 Press 0 for a zero or to clear R COMPUTERIZED SECURITY SYSTEM ARMED STATUS SYSTEM ARMED 01 01 97 12 00AM 1 2 4 3 5 6 7 8 9 0 A B C D E F G NEXT YES PRIOR NO AREA GEMINI E...

Страница 32: ...program the right segment only the left segment should display a blank Keep the Keypad Programming Worksheets on file for future reference General Programming Steps 1 Contact the central station to ascertain receiver format data format event codes subscriber numbers and telephone number s 2 Select the desired features by circling the respective address boxes Refer to the Programming Options and Wo...

Страница 33: ...TA ENTRIES 1 Enter the panel s Dealer Security Code Address 0500 then press the A button 2 Answer NO F to all questions until ACTIVATE PROGRAM Y N is displayed then press YES E NOTE If you pass ACTIVATE PROGRAM scroll backward using the the B button 3 Press the C button to enter the Address Program Mode Address 0000 will display 4 Press 1 2 1 8 to access Address 1218 The data for both digits will ...

Страница 34: ...tion each nibble Numbers in parentheses indicate data for selected zones or features See Programming Worksheets that follow DEFAULTS The defaults shown on the following pages are automatically set after exiting the Easy Menu Driven Mode ENTER DATA ADDRESS LOC LEFT RIGHT Program Option PROGRAMMING STEPS 1 Lookup desired Programming Option by Address Location highlighted in black 2 Select the progra...

Страница 35: ...T CHIME TIMEOUT sec Default blank 2 DATA ENTRIES LEFT RIGHT blank blank blank 2 blank 3 blank 4 blank 5 blank 6 blank 7 blank 8 F F TIMEOUT 0 sec 0 sec 2 sec sec 3 sec sec 4 sec 1 sec 5 sec 1 25 sec 6 sec 1 5 sec 7 sec 1 75 sec 8 sec 2 sec 255 sec 63 25 sec CHIME TIMEOUT OPTIONS Default blank blank ADDRESS 2408 LEFT RIGHT AC Fail Report Delay min DATA ENTRIES LEFT RIGHT blank blank blank 1 blank 2...

Страница 36: ...lay min KEYPAD SYSTEM CODES ADDRESS 0490 0495 0500 DEALER SECURITY CODE Enter up to 6 digits to be used by the dealer to enter programming 1 Enter in both left and right digits of address locations 2 Valid entries are 0 9 Note If left blank the Master Security Code must then be used to enter programming AMBUSH CODE Enter a 2 digit code used just prior to disarming and will activate an Ambush Condi...

Страница 37: ... CS RECEIVER 2 OPTIONS 1400Hz Handshake Kissoff 2300Hz Handshake Kissoff Enable Zone Number on Pulse Alarm Single Digit Only LEFT DATA VALUES CIRCLE 1 2 4 8 CS RECEIVER 2 OPTIONS Sum Check 3 1 with Extended Restores RESERVED RESERVED ADDRESS 0576 LEFT DIGIT SUM OF DATA VALUES RIGHT DIGIT SUM OF DATA VALUES RIGHT DATA VALUES CIRCLE 1 2 4 8 CS RECEIVER 3 OPTIONS 1400Hz Handshake Kissoff 2300Hz Hands...

Страница 38: ...not used 2 Valid entries are 1 9 0 10 B 11 C 12 D 13 E 14 F 15 NOTE Default is 15 Rings Dark shaded data shows option not available CALLBACK TELEPHONE NUMBERS Enter telephone numbers to be used when downloading from a computer 1 Enter in right digit only left digit is not used 2 Enter up to 20 digits from left to right NOTE Leave trailing boxes blank 3 Valid entries are 0 9 B button C button D 3 s...

Страница 39: ...CRIBER EVENT ID NUMBERS AREA 2 ADDRESS 0686 0689 RIGHT DIGITS 1 4 0686 0687 0688 0689 R R R R AREA 1 ADDRESS 0720 0723 RIGHT DIGITS 1 4 0720 0721 0722 0723 R R R R CS TELCO 2 SUBSCRIBER OPENING CLOSING ID NUMBERS BACKUP REPORTING AREA 2 ADDRESS 0724 0727 RIGHT DIGITS 1 4 0724 0725 0726 0727 R R R R AREA 1 ADDRESS 0752 0755 RIGHT DIGITS 1 4 0752 0753 0754 0755 R R R R CS TELCO 2 SUBSCRIBER EVENT ID...

Страница 40: ... Question ACCOUNT Default blank blank blank blank for all other ID Numbers CS TELCO SUBSCRIBER ID NUMBERS Enter the Subscriber Opening Closing and Event ID Numbers for any of the 3 CS Receivers 1 Enter in corresponding right digit address location left digit is not used 2 Enter 3 or 4 digits depending on the CS receiver format for each subscriber number from left to right NOTE Leave trailing boxes...

Страница 41: ...g Code CS AREA SYSTEM REPORTING OPTIONS ADDRESS 1024 1027 NOTE If neither TouchTone Dialing nor TouchTone w Rotary Backup is selected then system defaults automatically to Rotary Dialing Leave blank to select Rotary Dialing CS AREA SYSTEM REPORTING OPTIONS 1 Select the desired option by circling the data values for each digit left and right 2 Add the data values ex 15 1 2 4 8 from the selected opt...

Страница 42: ...4 Hour Auxiliary DATA ENTRIES LEFT 1 2 3 4 MODEM CODE Fire Panic Burglary Hold up ZONE REPORT CODE OPTIONS DATA ENTRIES LEFT RIGHT NOTE Zones 1 8 are included in the control panel and Zones 9 48 are EZM Zones See Address 2600 2605 to enable EZM Zone Groups PULSE EVENT CODE will be the first digit of the 2 digit reporting code the second digit will be the second digit of the reporting zone For exam...

Страница 43: ... 41 8 4 2 1 LEFT DATA VALUES User 40 User 39 User 38 User 37 8 4 2 1 ADDRESS 1034 LEFT RIGHT RIGHT DATA VALUES User 36 User 35 User 34 User 33 8 4 2 1 User Closing Telco 1 ADDRESS 1055 LEFT RIGHT blank RIGHT DATA VALUES User 00 User 99 User 98 User 97 8 4 2 1 User 97 Auto Arming Disarming User 98 Quickloader Arming Disarming User 99 Easy Arming Opening not applicable User 00 Keyswitch Arming NOTE ...

Страница 44: ...r 41 8 4 2 1 LEFT DATA VALUES User 40 User 39 User 38 User 37 8 4 2 1 ADDRESS 1060 LEFT RIGHT RIGHT DATA VALUES User 36 User 35 User 34 User 33 8 4 2 1 User Closing Telco 3 ADDRESS 1081 LEFT RIGHT blank RIGHT DATA VALUES User 00 User 99 User 98 User 97 8 4 2 1 User 97 Auto Arming Disarming User 98 Quickloader Arming Disarming User 99 Easy Arming Opening not applicable User 00 Keyswitch Arming NOTE...

Страница 45: ...RVD RSRVD 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 ADDRESS 1094 1104 LEFT ADDR RIGHT blank 1094 blank 1095 blank 1096 blank 1097 blank 1098 blank 1099 blank 1100 blank 1103 blank 1104 GLOBAL SYSTEM EVENT TROUBLE RIGHT DATA VALUES CIRCLE Telemetry Failure Telemetry Trouble RSRVD TELCO FAIL 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 Default...

Страница 46: ... 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 ADDRESS 1130 1137 LEFT ADDR RIGHT 1130 1131 1132 1133 1134 1135 1137 AREA 2 SYSTEM EVENT TROUBLE RIGHT DATA VALUES CIRCLE KEYPAD AUX KEYPAD FIRE KEYPAD PANIC AMBUSH 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 Defaults as circled from address 1120 1127 SYSTEM RESPONSE ACTIVATED BY AREA 1 EVENT TROUBLE Pulsed Burg Output Burglary Output Fire Out...

Страница 47: ...337 1338 1339 1340 1341 1342 1343 1344 1345 1354 1355 1362 1364 1375 1376 1386 ZONES 9 12 RIGHT DATA VALUES CIRCLE ZN12 ZN11 ZN10 ZN9 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 ...

Страница 48: ...35 1536 1537 1538 1539 1540 1541 1542 1543 1544 1545 1554 1555 1562 1564 1575 1576 1586 ZONES 25 28 RIGHT DATA VALUES CIRCLE ZN28 ZN27 ZN26 ZN25 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1...

Страница 49: ...35 1736 1737 1738 1739 1740 1741 1742 1743 1744 1745 1754 1755 1762 1764 1775 1776 1786 ZONES 41 44 RIGHT DATA VALUES CIRCLE ZN44 ZN43 ZN42 ZN41 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1...

Страница 50: ...0 ms Loop Response only available for zones 1 8 B 2 wire Smoke Detectors only available for zones 7 and 8 C If Fire Alarm Verification is selected then Fire must also be selected DEFAULTS The zone options indicated are automatically set after exiting the Easy Menu Driven Mode Priority Selective Bypass Alarm Output Auto Reset Swinger Shutdown Zone Area 1 and Zone Area 2 are enabled for the total nu...

Страница 51: ...SYSTEM OPTIONS Auto Bell Test on Arming Auto Reset after Burg Output Timeout Suppress Bypass Reminder when Armed RESERVED Default blank blank ADDRESS 2416 LEFT DIGIT SUM OF DATA VALUES RIGHT DIGIT SUM OF DATA VALUES blank System Options RIGHT DATA VALUES CIRCLE 1 2 4 8 RIGHT DATA VALUES CIRCLE 1 2 4 8 SYSTEM OPTIONS Enable Day Zone Watch Area 1 Enable Day Zone Watch Area 2 RESERVED RESERVED SYSTEM...

Страница 52: ...igits NOTE Dark shaded data value box shows option not available System Options LEFT DATA VALUES CIRCLE 1 2 4 8 RIGHT DATA VALUES CIRCLE 1 2 4 8 SYSTEM OPTIONS Disable System Trouble Audible at Keypad Chime on E4 Lug Disable Code required for Func Mode Lvl 1 Disable Code required for Easy Bypass Default blank blank ADDRESS 2422 LEFT DIGIT SUM OF DATA VALUES RIGHT DIGIT SUM OF DATA VALUES RIGHT DAT...

Страница 53: ...r data in left digit only SYSTEM OPTIONS ADDRESS 3882 3901 3903 3905 4084 Telephone Number Dialing Prefix Digits 1 20 ADDRESS 3882 3901 RIGHT DIGITS 1 20 3882 3883 3884 3885 3886 3887 3888 3889 3890 3891 3892 3893 3894 3895 3896 3897 3898 3899 3900 3901 R R R R R R R R R R R R R R R R R R R R Default blank blank ADDRESS 3903 LEFT RIGHT Pager Format Re sends of First Report Default blank blank ADDR...

Страница 54: ...AD AUXILIARY KEYPAD FIRE 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 KEYPAD OPTIONS ADDRESS 2425 2446 Keypad Options Default blank blank ADDRESS 2428 LEFT RIGHT blank Keypad 4 Type Area Assignment Default blank 1 ADDRESS 2425 LEFT RIGHT Keypad 1 Type Area Assignment Default blank blank ADDRESS 2426 LEFT RIGHT blank Keypad 2 Type Area Assignment Default blank blank ADDRESS 2427 LEFT RIG...

Страница 55: ...4 2 1 F 8 8 8 8 8 8 8 8 A4 A3 A2 A1 User Area Options USER NO 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 ADDRESS 2500 2547 L ADDR R 2500 2501 2502 2503 2504 2505 2506 2507 2508 2509 2510 2511 2512 2513 2514 2515 2516 2517 2518 2519 2520 2521 2522 2523 2524 2525 2526 2527 2528 2529 2530 2531 2532 2533 2534 2...

Страница 56: ...be programmed depending on the number of zones used and which EZM modules are connected Each group represents 4 zones 1 Select EZM type from the table shown 2 Enter in corresponding address locations above right digit only NOTE Dark shaded data value box shows option not available EZM PGM ARMED TERMINAL CONTROL For each zone group select the area s which when armed will activate the PGM Lug on the...

Страница 57: ...T DATA VALUES CIRCLE A2 A1 8 4 2 1 8 4 2 1 PRIORITY AREA ARMING REMOTE ACCESS LOGGING ADDRESS 3184 Default blank blank ADDRESS 3184 LEFT DIGIT SUM OF DATA VALUES RIGHT DIGIT SUM OF DATA VALUES LEFT DATA VALUES CIRCLE 1 2 4 8 SYSTEM OPTIONS Enable Keypad 5 Enable Keypad 6 Enable Keypad 7 RESERVED RIGHT DATA VALUES CIRCLE 1 2 4 8 SYSTEM OPTIONS Enable Keypad 1 Enable Keypad 2 Enable Keypad 3 Enable ...

Страница 58: ...value box shows option not available Area Output Control Default 2700 1 2708 1 OUTPUT SILENCED TURNED OFF Burglary Output Pulsed Burg Output Fire Output Reset Relay Auxiliary Relay LEFT DATA VALUES CIRCLE 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 ADDRESS 2700 2732 L ADDR R 2700 2708 2716 2724 2732 AREAS 1 2 RIGHT DATA VALUES CIRCLE A2 A1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 8 4 2 1 DISARMING AREA 1 TURNS...

Страница 59: ...40 min 570 min 600 min 630 min 660 min 690 min 720 min 750 min 780 min 810 min 840 min 870 min 900 min 930 min 960 min 990 min 1020 min 1050 min 1080 min 1110 min RF SUPERVISORY TIMERS DATA ENTRIES LEFT RIGHT 2 6 2 7 2 8 2 9 2 0 2 B 2 C 2 D 2 E 2 F 3 blank 3 1 3 2 3 3 3 4 3 5 3 6 3 7 3 8 3 9 3 0 3 B 3 C 3 D 3 E 3 F 4 blank 4 1 4 2 4 3 4 4 4 5 4 6 F F DELAY 1140 min 1170 min 1200 min 1230 min 1260 ...

Страница 60: ...nter Easy Menu Driven Program Mode to program system again GEM RP1CAe2 Keypad 4091 XX GEM RP2ASe2 Keypad 4091XX Cold Start Erases Entire Program This erases the entire program codes schedules foreign language configuration etc leaving the panel as it came right out of the box Access address 4093 then press the Jbutton Data entry is not allowed NOTE Some features schedules language configuration ca...

Страница 61: ...OGRAM MODE 1 Press EEEEEE A 2 Press g Until ACTIVATE PROGRAM Y N GEM RP1CAe2 or TURNON PROG Y N GEM RP2ASe2 appears on LCD screen 3 Press F To Enter User Program Mode 4 Press C To Exit User Program Mode when finished New Panel Default User Code 123 Existing Panel Any Code with User Program Option Enabled USER CODES Up to 48 User Codes may be programmed NOTE In this mode only the code is programmab...

Страница 62: ...9 If an old code is displayed program over it To erase the digit at the cursor press G 0 button Press the Jbutton to save the code in memory Repeat this procedure for each user To proceed to Zone Description programming press the NEXT E button GEM RP2ASe2 Keypad USER01 Direct Entry 123___ Programming User Codes GEM RP2ASe2 To Program User Codes 1 Enter 2 digit User Number 01 96 directly using numb...

Страница 63: ...figuration Mode 1 Move jumper JP5 located at the upper right corner of the control panel board from Pins 1 2 top two to Pins 2 3 bottom two NOTE See Wiring Diagram on page 75 2 After about 15 seconds the display will read XX OUT OF SYSTEM where XX indicates the keypad address 3 Press 11123 A and proceed as follows Repeat the following procedure for all keypads Keypad Tactile Beep Upon entering the...

Страница 64: ...DDRESS 00 display In multiple EZM systems enter an assigned group number 01 through 06 Each EZM must have a unique assigned group number starting with 01 and proceeding consecutively Press the Jbutton Press the A button to continue or press the C button to exit Zone Response The normal loop response of each keypad expansion zone is 750mS however the response time of any zone can be reduced to 50mS...

Страница 65: ...e keypad is installed Each must be assigned a unique address that is no two keypads may be numbered alike Keypads must be addressed consecutively that is missing numbers are not permitted Only Keypad No 1 may be used for programming However for ease of programming it is recommended that a GEM RP1CAe2 be selected as Keypad 1 Assign the keypad address number by selecting Jumpers J1 3 in accordance w...

Страница 66: ...ACTIVE BELL TEST 1 DISPLAY PHONE S 1 DISPLAY SYS TRBL 1 DISPLAY FIRE ALARM 1 DISPLAY FIRE TRBL 1 DISPLAY OP CL 3 ACTIVATE OVERVIEW 3 B ACTIVATE CHIME 1 ACTIVATE WATCH 2 RESET SYSTEM TRBL 3 RESET SENSOR MSG 3 START EXIT TIME 1 FAULT FIND C ACTIVATE LOCATE C EZM ZONE FIND C FUNCTION LEVEL A ACTIVATE DIALER TEST 3 DISPLAY ALARM LOG D 3 DISPLAY TOTAL LOG D 3 DISPLAY FIRE LOG D 3 DISPLAY OP CL LOG D 3 ...

Страница 67: ...YSTEM TRBL 3 RESET SENSOR MSG 3 START EXIT TIME 1 FAULT FIND C ACTIVATE LOCATE C EZM ZONE FIND C FUNCTION LEVEL A ACTIVATE DIALER TEST 3 DISPLAY ALARM LOG D 3 DISPLAY TOTAL LOG D 3 DISPLAY FIRE LOG D 3 DISPLAY OP CL LOG D 3 DISPLAY SYSTEM LOG D 3 TO ARM IN 1 4HRS 2 DISPLAY AUTO ARM SCHD 3 ACTIVATE PROGRAM 3 c ACTIVATE DOWNLOAD 3 DISPLAY RF XMITTER STAT 3 RELAY CONTROL 1 DEALER MODE Press Abutton E...

Страница 68: ...TERIOR ZONE NUMBERS E AREA 1 OF KEYPADS AREA 2 OF KEYPADS CENTRAL PHONE NO ACCOUNT _ _ _ _ RCVR FORMAT ENTER USER CODE ENTER ZONE DESCRIPTIONS RF XMITTER ID CODE POINTS KEY FOB ID CODE OPTIONS ENTER DATE MM DD YY ENTER TIME HH MMA P ENTER DEALER CODE EASY MENU MODE A Minimum level required to access function B Level 3 code with appropriate option C Requires dealer code D Not available in GEM RP2AS...

Страница 69: ...SET SENSOR MSG 3 START EXIT TIME 1 FAULT FIND C ACTIVATE LOCATE C EZM ZONE FIND C FUNCTION LEVEL A ACTIVATE DIALER TEST 3 DISPLAY ALARM LOG D 3 DISPLAY TOTAL LOG D 3 DISPLAY FIRE LOG D 3 DISPLAY OP CL LOG D 3 DISPLAY SYSTEM LOG D 3 TO ARM IN 1 4HRS 2 DISPLAY AUTO ARM SCHD 3 ACTIVATE PROGRAM 3 B ACTIVATE DOWNLOAD 3 DISPLAY RF XMITTER STAT 3 RELAY CONTROL 1 USER MODE Press Abutton USER CODES A Minim...

Страница 70: ...o Pins 1 2 SYSTEM READY Move Jumper JP5 from Pins 1 2 to Pins 2 3 Wait about 15 seconds OUT OF SYSTEM Configure Keypad Address Jumpers J1 J3 Touchpad Backlight Jumper A LCD Backlight Jumper B Entry Sounder Jumper C GEM RP2ASe2 KEYPADS JP5 is located at the top right corner of the circuit board If a Compatibility Number other than 0000 is programmed OLD COMPAT XXXX is displayed Keypad Programming M...

Страница 71: ...t Timeout Direct Address 2418 51 Auto Bypass Zone Option Direct Address 1204 1304 1404 1504 47 49 Auto Bypass Re Entry Zone Option Direct Address 1207 1307 1407 1507 47 49 Automatic Interior Bypass Direct Address 2421 52 Aux Output Access Control Timeout Direct Address 2402 35 Aux Output Chirp On Keyfob Arming Direct Address 2421 52 Aux Output Timeout Direct Address 2401 36 Auxiliary KP Report Cod...

Страница 72: ...dress 1025 41 Disable Code Required For Easy Bypass Direct Address 2420 52 Disable Code Required For Func Mode Lvl 1 Direct Address 2420 52 Disable Exit Entry Urgency Tone Direct Address 2422 52 Disable Fire Reset Area 1 Direct Address 2415 51 Disable Fire Reset Area 2 Direct Address 2415 51 Disable Function Mode Download Direct Address 2419 51 Disable Keypad Instant Button Direct Address 2420 52 ...

Страница 73: ...EOL Resistor Zone Option Direct Address 1239 1339 1439 2339 47 49 No Rings Before Pickup Direct Address 4089 38 Number Of RF Receivers Direct Address 3776 59 Number Of Zones Keypads Per Area Easy Menu Driven N A 6 7 Opening Report Code Direct Address 0866 40 Opening After Alarm Reporting Code Direct Address 0867 40 Opening Report Only After Alarm Report Direct Address 2417 51 Panel AC Failure Repo...

Страница 74: ...ackup Direct Address 1027 41 Transmit 402 Opening Closing Code Direct Address 1027 41 Trouble Report Code Direct Address 0861 40 Trouble On Night Open Direct Address 1243 1343 1443 2343 47 49 Trouble On Open Zone Option Direct Address 1241 1341 1441 2341 47 49 Trouble On Short Zone Option Direct Address 1242 1342 1442 2342 47 49 Trouble Restore Direct Address 0862 40 Trouble Restore 1 Zone Option ...

Страница 75: ... Wiring Diagram GEM P3200 WIRING DIAGRAM 8 3 VDC 4 AH 6 AH OR 7 AH R C O M P U T E R I Z E D S E C U R IT Y S Y S T E M GEMINI A R M E D S T A T U S S Y S T E M A R M E D 0 1 0 1 9 7 12 0 0 A M 1 2 4 3 5 6 7 8 9 0 A B C D E F G N E X T Y E S P R IO R N O A R E A GEM RP1CAe2 2 LINE LCD KEYPAD ...

Страница 76: ...her assumes nor authorizes any other person purporting to act on its behalf to modify to change or to assume for it any other warranty or liability concerning its products In no event shall NAPCO be liable for an amount in excess of NAPCO s original selling price of the product for any loss or damage whether direct indirect incidental consequential or otherwise arising out of any failure of the pr...