20
WI1089 GEM-P801 Installation Instructions
Press the [OFF] button to turn the Bell OFF.
4 PGM
Program a 4 in the AUX 1 and/or AUX 2
option to activate the PGM Output when the
[A1] or [A2] buttons on the Keyfob are
pressed. Press the [OFF] button to turn the
PGM Output OFF.
5 Instant
Program a 5 in the AUX 1 and/or AUX 2
option to activate Instant Mode when the [A1]
or [A2] buttons on the Keyfob are pressed.
6 Access on PGM
Program a 6 in the AUX 1 and/or AUX 2
option to activate the PGM Output for 5
seconds when the [A1] or [A2] buttons on the
Keyfob are pressed.
Addition programming required:
Enable
Access Output [
23-2]
7 Full Set System
Program a 7 in the AUX 1 and/or AUX 2
option to Fully Set the System when the [ON]
and the [A1]
or [A2] buttons on the Keyfob
are pressed, or when the [A1] or [A2] buttons
are pressed when the system is armed with
Exit/Entry Follower Zones
or
Home/Away
with Delay Zones
that have been bypassed.
Program an 8 in the AUX 1 and/or AUX 2
option to Bypass Exit/Entry Follower Zones
or Home/Away with Delay Zones when the
A1
A2
buttons on the Keyfob are pressed (only if
the system is programmed exclusively for
Home/Away with Delay Zones
).
[85] - [88] Wireless Smoke Detectors
Enter the RF ID# of the smoke detector.
A wireless smoke detector sends a
supervisory transmission about once every
hour. If the receiver does not receive a
signal from a transmitter in the time
programmed in Wireless Smoke
Supervisory Timer, a system trouble ‘RF
Smoke Supervisory Failure' will be
indicated on the keypad.
Program Wireless Smoke Supervisory
Timer [17] to change the time from the
default time of 8 hours. Refer to Household
Fire [96-3].
Note:
Mark Smoke Detectors (Smoke 1
through Smoke 4) in order to identify them
in the event of a supervisory or battery
failure. If
Household Fire
[96-4]
i
s selected,
Wireless Smoke Supervisory Time is fixed
at 4 hours.
Downloading
[90]Callback Telephone Number
Program the phone number of the
downloading computer to be dialed by the
panel during a high security download.
[91]Ring Count
Program the number of rings before the
panel will pickup.
Ring Method
[92-1]
(Downloading Features) must also be
selected.
[92]Downloading Features
(1) Ring Method
- Enable the ring method of
downloading. The panel will pick-up on the
number of rings programmed in
Ring Count
[91].
(2) Answering Machine Override
- Using
the downloading computer, call the panel.
When the operator has determined that the
panel has received 1-2 rings, pressing the
u
key will cause the downloading computer
to immediately re-dial the panel. The panel
will pick-up on the first ring.
(3) Function 6 Download
- Select to enable
the
A6
method of downloading (pg.
8).
(4) Signal Strength Test Mode
- Program to
initiate a 2 hour test period. The signal
strength information for all supervisory
signals received over a two hour period will
be saved to the LOG.
[93]Auto Download ID Number
Enter the Number that is used by PCPreset
when downloading using Site Initiated Auto
Downloading (
A6
).