13
permitted for UL installations.
[06]Disable EOL Resistor
Program this zone type if an End Of Line
Resistor is not required on the zone(s). If
programmed, a direct short across the zone
will cause the zone to set up normally.
This programming option is not permitted for
UL installations.
[07]Burg (Steady) Output
Enables the Bell Output on a zone trip for
each zone selected. The Bell Output will
remain ON for the length of time
programmed for
Burg (Steady) Output
[07]
or
it will remain ON until turned off by entering a
valid Arm/Disarm Code; 0 means output will
stay ON until reset.
[08]PGM Output
Enables the PGM Output on a zone trip for
each zone selected. The PGM Output will
remain ON until reset.
[09]Selective Bypass
If programmed, selected zones will be able
to be bypassed by the User. By default, all
zones are permitted to be bypassed.
System Times
[10]Exit Delay
The delay time which permits exit through an
Exit/Entry Zone
[00] after the system is
armed, allows a user to leave the premises
without
setting off an immediate alarm.
Exit Delay
may be programmed for up to
255 seconds (4¼ minutes); a value of 0
defaults to 60 seconds.
[11]Entry Delay
Delay time permits entry through
Exit/Entry
Zone(s)
after the system is armed without
setting off an immediate alarm.
Entry Delay
allows the user time to enter and disarm the
system. Upon entering, the keypad sounder
will sound a steady tone (Entry Sound) to
remind the user to disarm the system.
Entry Delay
Time
[11] may be programmed
for up to 255 seconds (4¼ minutes); a value
of 0 defaults to 30 seconds.
Entry Delay
may be canceled by pressing
F
before
or after arming.
[12]Burg (Steady) Output Time-out
Can be programmed from 1 to 255 min (4¼
hours); 0 means output will stay ON until
turned off by entering an Arm/Disarm Code.
[13]Fire (Pulsed/Temporal) Output T/O
Can be programmed from 1 to 255 min (4¼
hours); 0 for output active until silenced by
entering an Arm/Disarm Code. For
temporal sounder, enable [96-3] UL
Household Fire.
[14]Test Timer Interval
Test Timer
If Test Timer [36-4] is enabled, program the
interval, in days, between Test Timer reports.
Valid entries are from 1 to 255 days.
[15]Line Cut Time-to-Fail
Enable this feature by programming the
delay time required to declare a line cut
failure. Programming 000 will disable line
cut detection.
[16]Wireless Supervisory Timer
A transmitter will send a transmission every
time it is tripped; when there is no activity, the
transmitter sends a supervisory transmission
about once an hour. If the receiver does not
receive any signal (either a trip or a status)
from a transmitter in the time specified, a
system trouble ‘RF Supervisory Failure' will
be indicated at the keypad. Timer is
programmable from 1-26 hours; 0 means NO
supervision.
[17]Wireless Smoke Supervisory Timer
A smoke detector will send a transmission
every time it is tripped; when there is NO
activity, the smoke detector sends a
supervisory transmission about once an
hour. If the receiver does not receive a
signal (either a trip or a status) from a
transmitter in the time specified, a system
trouble ‘RF Supervisory Failure' will be