27
WARNING
TO PREVENT RISK
OF ELECTRIC SHOCK
DISCONNECT TELEPHONE
LINES PRIOR TO
This equipment should be installed in accordance with Chapter 2 of the National Fire
Alarm Code, ANSI/NFPA 72-1996 (National Fire Protection Association
Batterymarch Park, Quincy MA 02269). and local codes. Information describing
proper installation, operation, testing, maintenance, evacuation planning, and repair
service is to be provided with this equipment. UL Listed Energy Cable is required.
(Supervised)
To RJ31X
EARTH
GROUND
GEM-P801 Terminals
Fire
Loop In
4-Wire
Fire
Wiring
Power
Out (+)
Power
Out (-)
Power
In (-)
Fire Loop
Out
RED
BLACK
BROWN
BROW
FT2200
12
Power
In (+)
Fire Power
Ground
Fire Power
Fire
+
RED
BLACK
E1
E2
RECHARGEABLE
BATTERY
12 VDC 4AH OR 7AH
GEM-P801 WIRING DIAGRAM
(REFER TO INSTALLATION INSTRUCTIONS WI1089)
RESIDENTIAL BURG (4 HOUR STANDBY)
COMBINED STANDBY = 500 mA BELL = 2.0 A
RESIDENTIAL FIRE (24 HOUR STANDBY)
(2)
COMBINED STANDBY = 120 mA BELL = 95 mA
DS1
TEL LINE IN USE
RECOMMENDED BATTERIES YUASA
NP4-12 AND NP7-12
REPLACE EVERY FIVE YEARS
COLD WATER GROUND CONNECTION
USE ONLY COLD-WATER PIPE OR
BURIED GROUND ROD. USE AT LEAST
#16 AWG WIRE.
(1) COMBINED STANDBY = KEYPAD C AUX POWER
C FIRE POWER + PGM CURRENT.
(2) RESIDENTIAL FIRE REQUIRES A 7AH BATTERY.
(3) UNIT INTENDED TO BE MOUNTED VERTICALLY ON WALL.
(4) REFER TO WI1089 FOR COMPATIBLE TWO WIRE SMOKE
DETECTORS. DO NOT MIX DIFFERENT MODELS.
(5) THIS PANEL SHALL BE CHECKED BY A QUALIFIED
TECHNICIAN AT LEAST ONCE EVERY THREE YEARS.
(6) THIS PANEL SUPPORTS ONLY ONE SMOKE DETECTOR IN
ALARM.
(7) USE ONLY ONE BELL IN RESIDENTIAL FIRE APPLICATION.
(8) SYSTEM MUST BE TESTED AT LEAST ONCE A WEEK IN
THE AC/BATTERY MODE AND IN THE BATTERY-ONLY
MODE. (CONTACT CENTRAL STATION PRIOR TO
TESTING) AC MUST BE RESTORED AFTER TEST.
-4 +5 +6
1 2 +3
-10 +11 +12 -13 14 15
16 17 18 19
-7 +8 +9
ALL OUTPUTS ARE CURRENT LIMITED
2.2K
2.2K
2.2K
2.2K
2.2K
2.2K
ZONE
1 ZONE
2
ZONE
3 ZONE
4
ZONE
5 ZONE
6
16 VAC 20 VA
TRANSFORMER
NAPCO TRF12
(OR EQUIVALENT
SEE WI1089).
Class 2 Transformer
DO NOT connect
to switched outlet.
TELCO
JACK
10
12
13
GEM-RECV-XP8
(+)
+
FIRE
BELL
P
ro
gr
am
m
abl
e
Ou
tp
ut
PGM
(-)
16
+PWR
GND
+PWR GND GREEN
2.2K EOLR
2.2K EOLR
(SUPERVISED)
+
+
+
+
FIRE
PWR
LO
A
D
50 mA
M
AX
.
REMOTE BUS
RE
D
BL
K
GR
N
GEM-RP8
2.2K
2.2K
A
U
X
PO
W
E
R
O
U
T
P
U
T
10
-12.
5
VDC