Rev. 01 12/21
MagicControl 4.0 (CM40)
After filter pressure monitoring
•
95
316 B2 differential pressure monitor System pressure Δp
–
The differential pressure monitor measures the current system
pressure.
–
It is a measurement against atmosphere.
–
The pressure is displayed on the CM40 control at System pressure
Δp:
Actual value
–
The displayed value is evaluated for future applications.
The System pressure Δp is only displayed in Service Mode and
only in conjunction with the filter control cabinet type ICS08 or
ICS09.
315 B2 dynamic pressure monitor
–
The dynamic pressure monitor is an electrical pressure switch.
–
It is set to the
ATEX: Stop powder
switch-off point
315 B4 dynamic pressure monitor (redundant)
–
The dynamic pressure monitor is an electrical pressure switch.
–
It is set to the
ATEX: Stop powder
switch-off point
Pressure switch overview
Differential pressure monitor
System pressure Δp
(measurement against atmosphere)
Differential pressure monitor
Filter cartridge Δp
(filter resistance)
Dynamic pressure monitor
(redundant)
Electrical pressure switch
Pressure switch is set to:
Fan Δp
“ATEX: Stop powder”
Differential pressure monitor
(redundant)
Δp fan
Pressure switch is set to:
Fan Δp
“ATEX: Stop powder”
Dynamic pressure monitor
(measurement against atmosphere)
Electrical pressure switch
Pressure switch is set to:
Fan Δp
“ATEX: Stop powder”
Differential pressure monitor
Δp fan
Pressure switch is set to:
Fan Δp
“ATEX: Stop powder”
Fig. 94: Overview of all pressure switches with designations and intended use
Содержание CM40
Страница 28: ...Rev 01 12 21 28 Product description MagicControl 4 0 CM40 ...
Страница 64: ...Rev 01 12 21 64 Operation MagicControl 4 0 CM40 ...
Страница 82: ...Rev 01 12 21 82 Maintenance Repairs MagicControl 4 0 CM40 ...
Страница 92: ...Rev 01 12 21 92 Diagnostic MagicControl 4 0 CM40 ...
Страница 120: ...Rev 01 ...