Rev. 01 12/21
MagicControl 4.0 (CM40)
Maintenance / Repairs
•
79
Fig. 82: Powder output/powder hose correction
Station
Gun (
activated
/deactivated)
Powder output
Total air
Minimum powder output
Powder hose correction
Changes per gun or all guns at the same time
Exit current page
4.
Set the total air to
4.0
(Nm³/h) on the
(4)
display. Set the powder
output to
0
(%) on the
(3)
display
5.
Check the correction value for minimum powder output
C0
on the
(5)
display, and set it to
1.8
(Nm³/h) if necessary
6.
Check the correction value for maximum powder output
C1
on the
(6)
display, and set it to
100
(%) if necessary
For the next steps a measuring bag is necessary, for weighing
the powder output.
– Do not forget to note the dead weight of the measuring bag.
7.
Put the measuring bag over the gun nozzle and fasten it.
8.
Press the gun key
(2)
to switch on the gun for 60 seconds
9.
After this time has elapsed, switch off the gun, remove the
measuring bag and weigh it. The powder output should be between
10-15 gr
10. If no powder is expelled from the gun, increase the minimum powder
output value
C0
(range
0.5-3.0
Nm³/h)
11. If too much powder is expelled from the gun, decrease the minimum
powder output value
C0
(range
0.5-3.0
Nm³/h)
12. Repeat steps 7 and 8, until the powder output amounts to 10-15 g.
Annotate the adjusted minimum powder output value
C0
in the table
Содержание CM40
Страница 28: ...Rev 01 12 21 28 Product description MagicControl 4 0 CM40 ...
Страница 64: ...Rev 01 12 21 64 Operation MagicControl 4 0 CM40 ...
Страница 82: ...Rev 01 12 21 82 Maintenance Repairs MagicControl 4 0 CM40 ...
Страница 92: ...Rev 01 12 21 92 Diagnostic MagicControl 4 0 CM40 ...
Страница 120: ...Rev 01 ...