background image

Watchdog 100

Instruction Manual

geistglobal.com

Содержание Watchdog 100

Страница 1: ...Watchdog 100 Instruction Manual geistglobal com ...

Страница 2: ...y 11 Figures 11 Tables Chapter 1 Product Specifications 12 12 Product Specifications 12 Overview 12 Onboard Sensors 13 Analog I O Sensors 15 Remote Sensors 16 Environmental 16 Temperature 16 Humidity 16 Elevation 16 Electrical 17 Networking 17 Ethernet 17 Protocols 17 User Interfaces 18 Regulatory Compliance 18 Underw riters Laboratories UL 18 Federal Communications Commission FCC 19 RoHS WEEE Cha...

Страница 3: ...Network 47 Web Server 48 Time 49 Email 51 SNMP 52 Syslog 53 Admin 54 Locale 54 Utilities Chapter 4 Final Checkout 56 56 Final Checkout 56 Technical Support 56 Service and Maintenance 56 More Technical Support 57 Using Microsoft Exchange as an SMTP server 58 Product Specific Safety Notices 58 General Safety 58 Live Circuits Safety 59 Equipment Grounding 59 Electrostatic Discharge 59 Explosive Envir...

Страница 4: ...tware and documentation contained in this publication are copyrighted materials Recovery Act Buy American Geist products adhere to the Buy American provisions of the American Recovery and Reinvestment Act of 2009 Recovery Act All Geist goods manufactured in our Lincoln Nebraska plant have undergone substantial transformation during production Trade Agreements Act TAA Geist goods manufactured in ou...

Страница 5: ...nics supply chain becomes more fully documented Geist will not require that our direct suppliers source only conflict free minerals until an adequate number of smelters has been reliably identified and audited by The Electronic Industry Citizenship Coalition EICC and the Global e Sustainability Initiative GeSI to service the electronic industry supply chain Mandating a conflict free supply chain b...

Страница 6: ...s affiliates disclaim responsibility for any labor materials or costs incurred as a result of usage of this document Nor shall Geist a division of PCE Inc and its affiliates be liable for any damages inclusive of loss of profits or data arising from the use of or in connection with this document Geist a division of PCE Inc reserves the right to make changes to this document without notice to any u...

Страница 7: ...Geist document contains the following product information Product Specifications This chapter describes the major product characteristics and its functional role within the system Where appropriate reference to cabling among product components and to other Geist product s is provided Installation This chapter provides installation information for the preparation and use of Geist products as well a...

Страница 8: ...uthorization may be obtained on line from the RMA Form link located within the Geist Support site Reporting Document Errors Should you discover any error or identify a deficiency in this document please take time to contact us at the following email address Geist Documents geistglobal com Please be sure to provide us with the document name part number and page number s Also please provide us with ...

Страница 9: ...oduct Classification o Power Distribution Unit Basic Monitored only Switched only Monitored Switched o Environmental Monitoring o Cooling o Data Center Infrastructure Management DCIM Figure 1 Overlay Symbology Guide Figure 1 The chart above depicts the symbols used on Geist overlays ...

Страница 10: ... The representations are DANGER INDICATES AN IMMINENT HAZARDOUS SITUATION WHICH IF NOT AVOIDED WILL RESULT IN DEATH OR SERIOUS INJURY WARNING INDICATES A POTENTIAL HAZARDOUS SITUATION WHICH IF NOT AVOIDED COULD RESULT IN DEATH OR SERIOUS INJURY CAUTION INDICATES A POTENTIAL HAZARDOUS SITUATION WHICH IF NOT AVOIDED COULD RESULT IN PRODUCT DAMAGE AND MINOR TO MODERATE INJURY NOTE Provides useful inf...

Страница 11: ...gure Chapter Image Example Figure 1 1 Name and or Title goes here Tables Tables presented in this document are identified and designated as follows Table Chapter Image Example Table 1 1 Name and or Title goes here Column 1 Column 2 Column 3 Column 4 Column 5 Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text ...

Страница 12: ...Additionally the Watchdog 100 provides one output relay that can be operated remotely or set to automatically open or close based on alarm conditions The Watchdog 100 supports Power Over Ethernet PoE All internal and external sensors are measured every 5 seconds Sensor data collected by Watchdog 100 units provides useful trend analysis data While all values are not absolute in relation to a known ...

Страница 13: ...og 100 P Analog I O Sensors The Watchdog 100 units come equipped with four Analog I O ports for connecting additional external sensors such as Flood and Door Sensors The four ports are designed to accept a 0 5 Vdc analog input alternatively an internal 100K pull up resistor to 5 V allows for the use of dry contacts The Analog I O port input is converted to a digital number ranging from 0 to 99 and...

Страница 14: ...1 3 Flood Sensor Wiring Figure 1 4 Door Sensor Wiring Available Analog I O Sensors FS Flood Sensor RDPS Door Sensor SA 1 Smoke Alarm RCP 2 125 VAC City Power Monitor WSK 10 10 Water Sensing Cable Kit WSK 40 40 Water Sensing Cable Kit 48 IVS DC Isolate Voltage Sensor 48Vdc 30 VDCM Power Monitor ...

Страница 15: ...t may be used outside of the US Connecting Remote Sensors Plug and play remote sensors may be attached to the unit at any time via the RJ 12 connectors on the face of the unit In some cases splitters may be required to add additional sensors Each sensor has a unique serial number and is automatically discovered and added to the web page Up to four sensors may be connected to the Watchdog 100 The d...

Страница 16: ... F 65 C 149 F Humidity Table 1 2 Humidity Limits Minimum Maximum Operating 5 95 non condensing Storage 5 95 non condensing Elevation Table 1 3 Elevation Limits Minimum Maximum Operating 0 m 0 ft 2 000 m 6 561 ft Storage 0 m 0 ft 15 240 m 50 000 ft Electrical 6 12 Volts DC 2 Amps Power Over Ethernet PoE Enabled Class 0 Output Relay Contact Ratings The output relay contacts are intended to carry low...

Страница 17: ...ions CAUTION Consideration should be given to lockout tagout and other procedures required for servicing external devices controlled by the Watchdog 100 output relays Appropriate safety precautions must always be taken when operating or maintaining equipment connected to the Watchdog 100 Geist assumes no responsibility or liability for any injury or damage to any persons or property resulting from...

Страница 18: ...television wire satellite and cable in all 50 states the District of Columbia and U S territories An independent U S government agency overseen by Congress the commission is the United States primary authority for communications laws regulation and technological innovation The FCC standards specific to this equipment are This Class A device complies with part 15 of the FCC Rules Operation is subje...

Страница 19: ... in the European Union and restricts the use of six hazardous materials found in electrical and electronic products All applicable products in the EU market after July 1 2006 must pass RoHS compliance RoHS impacts the entire electronics industry and many electrical products as well RoHS specifies maximum levels for the following six restricted materials Lead Pb 1000 ppm Mercury Hg 100 ppm Cadmium ...

Страница 20: ...0 has a default IP address for initial setup and access Once you have assigned an IP address the default IP address will no longer be active To restore the default IP address and reset all user account information if the user assigned address or passwords are lost or forgotten press and hold the network reset button located to the right of the Ethernet port for 15 seconds To completely erase ALL o...

Страница 21: ...trol Panel Network and Sharing Center Change Adapter Settings Windows 8 Server 2012 Move the mouse cursor to the bottom or top right corner of the screen click the Settings icon then select Control Panel Change the view type from Category to Large or Small Icons if necessary then select Network and Sharing Center then Change Adapter Settings Windows 10 Click the Start button then choose Network In...

Страница 22: ...in the list then click the Properties button to open the Internet Protocol Properties window If you see more than one TCP IP entry as in the example above the computer may be configured for IPv6 support as well as IPv4 make sure to select the entry for the IPv4 protocol Write down the current NIC card settings so you can restore them to normal after you have completed the setup procedure ...

Страница 23: ...bar of your web browser If you are setting up the unit for the first time or if the unit has been reset back to factory defaults via the network reset button the unit will require you to create an Admin account and password before you can proceed Once you have created an Admin account and have logged into it the unit s default Sensors page should come up by default Navigate to the System tab then ...

Страница 24: ...twork and internet settings Mac Click the System Preferences icon on the Dock and choose Network Figure 2 4 Mac System Preferences Be sure Ethernet is highlighted on the left side of the NIC window In most cases there will be one Ethernet entry on a Mac Write down the current settings so you can restore them to normal after you have completed the setup procedure Select Manually from the Configure ...

Страница 25: ...s page should come up by default Navigate to the System tab then the Network page to configure the device s network properties The unit s IP Address Subnet Mask Gateway and DNS settings can either be assigned manually or acquired via DHCP The new settings will take effect when the Save button is clicked so the browser will no longer be able to reload the web page from the 192 168 123 123 address a...

Страница 26: ... appear below the internal sensors when attached Figure 3 1 Sensors Overview Page 1 Geist Logo Clicking on this logo from any page will reload the Sensors Overview page 2 Sensors System and Help Tab Mouse over to show sub menus Sensors Available options are Overview this page Alarms and Warnings Cameras Logging and Data Graphing System available options are Users Network Web Server Time Email SNMP...

Страница 27: ...State Temperature Humidity and Dew Point of connected sensors 8 Relay Displays and configure relay state Energize De energize The Watchdog 100 has one relay that can be operated remotely or set automatically opened or closed based on alarm conditions Friendly names for the relay give the option of changing the state name from Energized De energized to something more meaningful to user Figure 3 2 I...

Страница 28: ...perature Offset as needed Name is the device s factory name or model and cannot be changed 2 Once done click Save Figure 3 3 Device Labeling and Temperature Offset Deleting a Sensor This device and associated data and configuration can be deleted by clicking the delete icon and following the confirmation prompt The deleted device must be removed otherwise it will be re detected and shown on the pa...

Страница 29: ...ted remotely or set to automatically open or closed based on alarm conditions A relay in non latching mode will automatically energize and de energize as its associated alarms trip and clear A relay in latching mode will similarly energize on an alarm trip but will only de energize when acknowledged by the user on the Alarms and Warning page See Add Modify Alarms and Warnings for additional inform...

Страница 30: ...ck on the Configuration icon 2 Change label to desired name 3 Select desired mode a Alarm Control Act according to Alarms and Warning settings b Manual Control Enable user to force the relay to energize or de energize See Relay Manual Control Setting below 4 Change label of Energize De energize to desired name 5 Click Save when done ...

Страница 31: ...Relay Manual Control Setting Figure 3 6 Relay Control Setting 1 Click on the Setting icon 2 Change Operation to desired relay condition On Energized Off De energized Notice the State label This describes the current state of the relay 3 Click Submit to commit the change ...

Страница 32: ...indicates that this particular Warning Event has been tripped A tripped Warning Event displays in orange This symbol indicates that this particular Alarm Event has been tripped A tripped Alarm Event displays in red This symbol indicates that this Event has been acknowledged by user after being tripped It will remain this way until the condition being measured by this Event returns to normal i e ce...

Страница 33: ...M1118 Watchdog 100 Instruction Manual NOTE Clicking this symbol does not clear the Warning or Alarm Event it just stops the notifications from repeating 4 The actual conditions for the various Alarms Warnings settings are shown here ...

Страница 34: ...t on b Select the measurement temperature humidity etc you want to Trigger the Event c Set the Severity level Warning or Alarm for this Event d Select the threshold Type high trips if the measurement goes above the threshold or low trips if the measurement goes below the threshold e Type in the desired Threshold Value any number between 999 0 999 0 is valid f Type in the desired Clear Delay time i...

Страница 35: ... set specific times an Event will trigger a notification Multiple Valid Time entries can be set allowing users to set alerts to notify different Targets based on time of day or day of week j To determine where the alert notifications will be sent to when this particular Alarm or Warning Event occurs click the Add icon to create a new Action then select the desired options from the drop down menu F...

Страница 36: ...Repeat determines whether multiple notifications will be sent for this Event Action Repeat notifications are sent at the specified intervals until the Event is acknowledged or until the Event is cleared and reset The Repeat interval can be up to 14400 seconds 4 hours A Repeat of 0 disables this feature and only one notification will be sent Then click Save to save this notification Action More tha...

Страница 37: ...d column at the far left The default is unchecked disabled when you first add each Action set the checkbox to enable it This allows you to selectively turn different Actions on and off for testing To delete an existing Alarm or Warning Event Click the Delete icon next to the Alarm or Warning Event you wish to change then click Delete to confirm Figure 3 12 Delete Action Page ...

Страница 38: ...r to add IP addressable network cameras for remote monitoring Up to four IP addressable network cameras can be added NOTE Some cameras require additional software downloads to display live video in a web browser Each camera must be set to allow anonymous access to enable this feature Clicking on the camera image opens the camera s website in a new browser window Figure 3 13 Cameras Page ...

Страница 39: ...n Figure 3 14 Add a Camera 2 Set the desired conditions for this Event as follows a Enter the URL of the online camera b Select the Make Model of camera you are connecting to c Enter the Username if necessary d Enter the Password if necessary 3 Click Save Modifying a camera 1 Click the Modify icon Figure 3 15 Modify a Camera ...

Страница 40: ...ick Delete to confirm Figure 3 16 Delete a Camera Logging The Logging Page allows the user to download the historical data recorded by the unit Recorded data is available for download in Comma Separated Values CSV or JavaScript Object Notation JSON file types Data is written to the log every 60 seconds however all sensor data used in by the real time display and alarm functions is read at least on...

Страница 41: ...wnload Data Log 1 Right click on the desired data type 2 Choose Save link as 3 Follow save link prompt Figure 3 18 Download Data Log Clear Data Log 1 Click Clear the Log button Figure 3 19 Clear Data Log NOTE All previously recorded data will be deleted 2 Confirm deletion ...

Страница 42: ... Graph The Data Graph page allows a user to display the historical data from the data log in graph format Figure 3 20 Data Graph Configuring Graph 1 Click the desired measurement to highlight it 2 Choose the Time Range 15 minutes to 30 days 3 Click Display Refresh button to display changes ...

Страница 43: ...Account Page There are three buttons available on the User Accounts page 1 Add New User Account 2 Modify User s Account 3 Delete User s Account NOTE Only an Administrator level account can Add Modify or Delete users Control level and View Only accounts can change their own passwords via the Modify button but cannot Add or Delete accounts or Modify other accounts The Guest account cannot Add Delete...

Страница 44: ...ng c Control if set to True this account has Control level access Setting Administrator to True will automatically set Control to True as well Setting this to False makes the account a View Only account d New Password account passwords may be up to 24 characters long are case sensitive and may not contain spaces e Account Status set the account to Enabled or Disabled Disabling an account prevents ...

Страница 45: ...language for their own account View Only accounts cannot change any device or system settings Guest Anyone who brings up the unit s web page without logging in will automatically be viewing the unit as Guest By default the Guest account is a View Only account and cannot make changes to any settings although the Administrator can elevate the Guest account to Control level access if desired allowing...

Страница 46: ...lic internet network This is required if the unit needs to reach any services on the internet such as a public email or NTP server If DHCP is Enabled this field will automatically be filled in when the DHCP service assigns the unit an IP address IP Address Displays the IPv4 and IPv6 addresses currently being used by the unit Clicking on the Modify icon will allow you to change the unit s IPv4 addr...

Страница 47: ... the new IP address into the browser s address bar and the unit will be accessible Web Server The unit s Web Server configuration can be updated on the Web Server tab of the System menu Figure 3 25 HTTP Configuration Page HTTP Interface Enables disables access via HTTP HTTPS interface will always be enabled Available options are Enabled or Disabled It is not possible to disable the web interface c...

Страница 48: ...it attempts to contact the time servers during boot up and periodically while running All log time stamps will present time as the number of seconds since the unit was powered up until a time server is contacted or the system clock is manually set Figure 3 26 HTTP Clock Setting Manually Setting System Clock 1 From the Mode click the drop down text box and select Manual 2 Enter the Date and Time in...

Страница 49: ...e name or IP address of a suitable SMTP or ESMTP server Port The TCP port which the SMTP Server uses to provide mail services Typical values would be port 25 for an unencrypted connection or 465 and 587 for a TLS SSL encrypted connection but these may vary depending on the mail server s configuration Enable SSL If Enabled the unit will attempt to connect to the server using a fully encrypted TLS S...

Страница 50: ...the Exchange server will need to be set to allow Basic Authentication so that the unit will be able to log in with the AUTH LOGIN method of sending its login credentials Other methods such as AUTH PLAIN AUTH MD5 etc are not supported Figure 3 28 Email Target Configuration Page To Add or Modify a Target Email address 1 Click on the Add or Modify icon 2 Type email address and then click Save To Dele...

Страница 51: ...ault for SNMP services this can also be changed if desired The Management Information Base MIB can be downloaded from the unit if needed via the MIB link at the top of the web page Clicking this link will download a ZIP archive containing both the MIB file itself and a CSV formatted spreadsheet describing the available OIDs in a human readable form to assist you in setting up your SNMP manager to ...

Страница 52: ...e trap should be sent to in the Host field change the Port number if required select the trap Version to be used v1 v2c or v3 and click Save A test trap may be sent by clicking on the Test icon next to the Host IP address Trap settings can also be updated changed by clicking the Modify icon next to the Host IP address Syslog Syslog data can be captured remotely but must first be setup and enabled ...

Страница 53: ...users can view the information Also the System Label can be modified on this page This label is typically shown in the title bar of the web browser s window and or on the browser tab s currently viewing the device NOTE This information is strictly for the users and administrator s convenience The unit will not attempt to send emails to the Administrator Email address and this address cannot be cho...

Страница 54: ...em menu provides the ability to restore defaults reboot the communication system and perform firmware updates The Restore Defaults section allows the user to restore the unit s settings to the factory defaults There are two options All Settings erases all of the unit s settings including all Network and User Accounts settings effectively reverting the entire unit back to its original out of the bo...

Страница 55: ...are You can also subscribe to a mailing list to be notified of when firmware updates become available Figure 3 42 Firmware Update Page Firmware updates will typically come in a ZIP archive file containing several files including the firmware package itself a copy of the SNMP MIB a readme text file explaining how to install the firmware and various other support files as needed Be sure to un ZIP th...

Страница 56: ... here Figure 3 43 Info Page Service and Maintenance No service or maintenance is required Do not attempt to open the Watchdog 100 or you may void the warranty There are no serviceable parts inside the Watchdog 100 More Technical Support http geistglobal com Americas 1 888 630 4445 Europe and Middle East From within the UK 0845 026 3853 From abroad 44 845 026 3853 Asia English 1 888 630 4445 US num...

Страница 57: ...t Your Exchange server may also need to be configured to allow messages to be relayed from the monitoring unit Typically this will involve turning on the Reroute incoming SMTP mail option in the Exchange server s Routing properties then adding the Watchdog 100 s IP address as a domain which is permitted to relay mail through the Exchange server More information about enabling and configuring SMTP ...

Страница 58: ...ic procedural safety precautions relating to this product are stated below General Safety Safety is a serious matter and all precautions should to taken to guarantee a safe work and operational environment General safety precautions must be observed during all aspects of operation service and repair of equipment described in this document Failure to comply with the safety warnings procedures and g...

Страница 59: ...rth ground wire typically green must be firmly connected to the facility electrical safety ground The mating electrical interface to this equipment must comply with International Electromechanical Commission IEC standards Electrostatic Discharge Geist strongly recommends that an anti static precautions be taken when installing removing or working on and around static sensitivity equipment Industry...

Страница 60: ... parts or sub assemblies Any adjustments should be made by authorized service personnel only Repairs and Modifications Because of the danger of electrocution and or severe health hazard do not install substitute parts or preform any unauthorized modifications of this equipment It is best to contact Geist for Warranty and Repair Service to ensure that safety features are maintained ...

Страница 61: ...Thank You For Purchasing Geist geistglobal com ...

Отзывы: