300 Z/ZP 2
Operation
BL144 GB 2019-11
73
4.3.6
Controls for special operation
4.3.6.1
Operation for assembly
For assembly, it is only possible to operate the hoist from the platform in
dead man's control. The platform only operates while the operating
button is pressed.
The ramp, barrier with unloading ramp and assembly plank must be
closed and engaged. The assembly guard must be properly attached at
the top.
Turn the main switch (on the ground station switch box) to the "I"
position (ON).
The key switch (10) must be turned to
the right ("1" position).
The LED display (7) of the selected
operating mode lights up.
Fig. 44: Selector switch for operating
mode, assembly
In this position, the key cannot be removed.
Only the platform control is activated for assembly.
WARNING
Key for authorized persons
The key (10) may only be used by assembly and maintenance
personnel!