![GE T17 Скачать руководство пользователя страница 73](http://html.mh-extra.com/html/ge/t17/t17_installation-manual_127652073.webp)
Model T17 Installation Guide
65
Chapter 4. Inserting T17 Transducers into the Pipe
4.2.3 Aligning the Downstream Transducer for Extended Range Installations
For extended velocity range applications, the head of the downstream transducer is angled at 6° so that it points
upstream (into the flow) by 6°. This allows the ultrasonic signal to be pushed into alignment at very high flow rates. At
low flow rates, the beam is wide enough to tolerate the initial 6° misalignment.
Note:
Only the downstream transducer flange alignment is crucial to the functionality of the meter. For installation
of the upstream transducer, see “Mounting the Insertion Mechanism” on page 58.
Note:
This step of the installation requires two people. One person should support the barrel and one person should
operate the alignment fixture.
1.
Locate the supplied
alignment tool
below (part number
568-120
). This tool is used to check
and fine-tune (if necessary) the transducer alignment by rotating the
Barrel Assembly
prior to final tightening
of the mounting nuts and studs.
Note:
Although this process ensures optimum performance, it is not required for proper operation.
Figure 75: Alignment Tool
2.
Find the scribe line on the downstream transducer tube near the transducer end with the BNC connector. This
scribe line indicates the direction of the angled transducer head. Verify by direct observation that the scribe line
on the transducer lines up with the alignment marking on the flange at the top of the Barrel. If it does not,
contact GE for assistance.
CAUTION!
Although the images in this section do not show the gasket referenced in
, that gasket is crucial to sealing the assembly.
Содержание T17
Страница 1: ...GE Oil Gas Flow 916 128 Rev D September 2020 Model T17 Ultrasonic Flow Transducer Installation Guide ...
Страница 2: ......
Страница 4: ...ii no content intended for this page ...
Страница 62: ...Chapter 2 Installing the Pipe Nozzles 54 Model T17 Installation Guide no content intended for this page ...
Страница 64: ...Chapter 3 Installing an Isolation Valve 56 Model T17 Installation Guide no content intended for this page ...
Страница 88: ...Chapter 6 Specifications 80 Model T17 Installation Guide no content intended for this page ...
Страница 90: ...Warranty 82 Model T17 Installation Guide no content intended for this page ...
Страница 92: ......
Страница 93: ......