RSDetection
User’s Manual
March 2016
S131-200-UM Rev A
Page 70
g
Command
Support
Comments
Itself
E
Yes
Same as ‘D’ command except the averaging buffer is not reset.
Command
#E0<CR>
Response
E Y 0 SSSS HHHH BB.BB AAAAA EEEE CC<CR><LF>
L
Yes
Retransmits the last “D” response, with an “L” instead of “D”.
Command
#L0<CR>
Response
L Y 0 SSSS HHHH BB.BB AAAAA EEEE CC<CR><LF>
8.6.3
“M” Commands
Table 23 "M" Command Support
Command
Support
Comments
M0
Yes
Transmits the entire data buffer (maximum 500 points) to the
interrogating device. An example of the first few lines is below.
The first line indicates the number of points followed by
recording interval in seconds. The remained values corresponds
to the ‘D’ command response
Command
#M00<CR>
Response
00125 00015 0000 0000 06.80 00.00 00.00 00028<CR>
.0125 .0122 .0136 .0142 .0137 .0129 .0130 .0131 .0131 .0127
00077<CR>
.0127 .0126 .0132 .0131 .0140 .0135 .0130 .0122 .0122 .0127
00068<CR>
….
M1
Yes
Resets the data buffer
Command
#M01<CR>
Response
M01<CR><LF>