6000 & 7000 Series DISHWASHERS
PAGE 10
3.1 GENERAL SPECIFICATIONS
3.1.1 Control System
All control and interface boards operate at 120v.
3.1.1.1 6400 & 6500 Models
The controller has eight surface mounted switches.
The control switches are:
Nine surface mounted green LED’s illuminate and display the
actual wash, water temperature, dry, and delay mode.
Five surface mounted green LED progress indicators illumi-
nate and display the actual wash mode as follows.:
SENSING WASHING RINSING DRYING CLEAN
All off board components are triac controlled, except the
wash motor relay and the heating element for heating and
drying which is also relay controlled.
3.1.1.2 6700 & 6900 Models
The controller has eight surface mounted switches.
The control switches are:
Ten surface mounted green LED’s illuminate and display the
actual wash, water temperature, dry, and delay mode.
Five surface mounted green led progress indicators illumi-
nate and display the actual wash mode as follows:
SENSING WASHING RINSING DRYING CLEAN
All off board components are triac controlled, except the
wash motor relay and the heating element for heating and
drying which is also relay controlled.
3.1.1.3 6905 Model
The controller has eight surface mounted switches.
The control switches are:
Ten surface mounted green LED’s illuminate and display the
actual wash, water temperature, dry, and delay mode.
Five surface mounted green LED progress indicators illumi-
nate and display the actual wash mode as follows:
SENSING WASHING RINSING DRYING CLEAN
All off board components are triac controlled, except the
wash motor relay and the heating element for heating and
drying which is also relay controlled.
3.0 SPECIFICATIONS
3.1.1.4 6600 Model
The controller has two large surface mounted rotary encod-
ers for wash cycles and heat options and a smaller surface
mounted switch for push button start.
The control switches are:
Two surface mounted red LED’s illuminate and display the
actual wash cycle and heat option selected.
All off board components are triac controlled, except the
wash motor relay and the heating element for heating and
drying which is also relay controlled.
3.1.1.5 6605 Model
The controller has two large surface mounted rotary encod-
ers for wash cycles and heat options and a smaller surface
mounted switch for push button start.
The control switches are:
Two surface mounted red LED’s illuminate and display the
actual wash cycle and heat option selected.
All off board components are triac controlled, except the
wash motor relay and the heating element for heating and
drying which is also relay controlled.
3.1.1.6 7000, 7005, 7100, & 7105 Models
The controller has eight surface mounted switches.
The control switches are:
Ten surface mounted green LED’s illuminate and display the
actual wash, water temperature, dry, and delay mode.
All off board components are triac controlled, except the
wash motor relay and the heating element for heating and
drying which is also relay controlled.