6000 & 7000 Series DISHWASHERS
PAGE 59
5.2.41 Door Handle - 6400, 6500, 6700, 6900 & 6905
Models
CAUTION. Switch off electrical power supply.
5.2.41.1 For Models 6400 and 6500 remove Control Panel.
For Models 6700, 6900 and 6905 remove Door Panel.
Remove Dress Panel LH Side and Dress Panel RH Side
(Section 5.2.45).
Door Handle.
5.2.41.2 Compress the detent clip of the leaf spring on the
end adjacent to the Door Lock Micro Switch.
5.2.41.3 Slide the leaf spring through two retaining slots
formed in the Control Panel Carrier Frame. It will be required
to compress detent clip again in order to pass through
opposite side slot. Lift leaf spring clear.
5.2.41.4 Grasp Door Handle on one end and lift outward to
unclip spigot from Control Panel Carrier Frame.
5.2.41.5 With one door handle spigot unclipped from the
Control Panel carrier frame retainer, exert pressure on to the
opposite side to release the Door Handle. Lift the Door
Handle clear.
5.2.41.6 Reassemble the dishwasher in reverse order.
5.2.42.7 Operate and test dishwasher before leaving.