6000 & 7000 Series DISHWASHERS
PAGE 51
5.2.31 Turbidity Sensor
All models except 6605, 6905, 7005 & 7105
CAUTION. Switch off electrical power supply
and turn off water supply at main or isolating
valve.
5.2.31.1 The turbidity sensor is located in-line in the wash
pump to bypass filter hose. To remove the turbidity sensor
release the two hose clamps (one at each end of the sensor).
Slide the hoses off at each end of the sensor. Disconnect the
electrical plug and lift the sensor clear.
Turbidity Sensor Hose Clamp
Wash Pump to Bypass Filter Hose
5.2.32 Air dome
CAUTION. Switch off electrical power supply
and turn off water supply at main or isolating
valve.
5.2.32.1 The air dome is located in a spigot on the sump at the
front of the cabinet. To remove the air dome release the
plastic sump clip locking the air dome in position sliding it out
of the spigot and lifting it clear, remove the pressure switch air
dome hose.
5.2.32.2 Reassemble the dishwasher in reverse order.
Note: Ensure when reassembling the air dome that the
o-ring seal and sump spigot are smeared with Vaseline
jelly to prevent the o-ring from rolling over.
O-ring seal
Sump Spigot Air Dome
5.2.31.2 Reassemble the dishwasher in reverse order.
CAUTION. Test for water leaks before leaving.
5.2.31.3 Operate and test dishwasher before leaving.
CAUTION. Test for water leaks before leaving.
5.2.32.3 Operate and test dishwasher before leaving.