6000 & 7000 Series DISHWASHERS
PAGE 52
5.2.33 Water Inlet Solenoid Valve
CAUTION. Switch off electrical power supply
and turn off water supply at main or isolating
valve.
The water inlet solenoid valve is a special purpose
component and is NOT to be interchanged with other
water inlet solenoid valves.
The delivery of the water inlet solenoid valve is rated at a
nominal 1.25 US gallons per minute. Do not use any other
type of water inlet solenoid valve.
5.2.33.1 Refer to section 5.1 for access to remove the Water
Inlet Solenoid Valve.
5.2.33.2 From the front of the dishwasher, remove the two
mounting screws which retain the Water Inlet Solenoid Valve
to the flange on the mains terminal compartment.
Lift the valve clear.
5.2.33.3 Disconnect the two 1/4" terminals as shown below.
Air Dome Mounting screws
Mains terminal compartment flange
5.2.33.4 Compress the hose clamp which retains the con-
necting hose and slide the clamp from the spigot.
5.2.33.5 Grasp the hose and remove it from the spigot of the
Water Inlet Solenoid Valve.
5.2.33.6 Lift the Water Inlet Solenoid Valve clear of the
dishwasher.
5.2.33.7 Reassemble the dishwasher in reverse order.
CAUTION. Test for water leaks before leaving.
5.2.33.8 Operate and test dishwasher before leaving.
5.2.34 Drain Pump - Removal
The Drain Pump is a self contained motor and pump assembly
mounted directly into the Sump by the induction or inlet spigot
equipped with a neoprene multi-lipped cylindrical seal to
prevent water leakage. A single Phillips head screw retains the
complete motor and pump to the Sump. Removal of the Drain
Pump is accomplished by the following procedure:
CAUTION. Switch off electrical power supply
and turn off water supply at main or isolating
valve.
5.2.34.1 Refer to section 5.1 to gain access to the Drain
Pump.
5.2.34.2 Disconnect the two Quick Connect terminals and
wires from the 1/4" tabs marked “L&N” mounted on the
encapsulated field windings of the Drain Pump Motor. The tab
marked “L” should be connected to the wiring harness wire
marked “G2-D” (Drain) which is connected directly to the
Overfill Switch. The neutral of the Drain Pump marked “XN-D”
should be connected directly to the “N” of the mains terminal
block. For rotary models the neutral wire is marked W2-D and
connects to the N of the mains terminal block via the Wash
Pump Motor plug.