MobileView User Manual
2 Hardware Installation
1036564B / October 2002
17
2.7 I
NSTALLING THE
P
ANIC
B
UTTON
(
OPTIONAL
)
The Panic Button is typically installed within reach of the driver.
Note:
There are two versions of the panic button: one with a key reset and one without. See Figures 19 and 20.
1)
Using the panic button as a template, mark the location of the two mounting holes.
2)
Using a 3/16-inch (5 mm) drill bit, drill the mounting holes.
3)
Using a 3/4-inch (20 mm) drill bit, drill a hole for the panic button’s wiring.
4)
Splice a six-conductor 18 AWG cable to the panic button’s wiring.
Note:
The panic button with key reset (Figure 19) has six wires, and the panic button without key reset (Figure 20) has only five.
The N/C and common wires are both yellow and are interchangeable.
5)
Route the cable to the DVR. Connections to the J11 terminal of the DVR back box are as follows:
N/C and common (2 wires, both yellow) to terminals 3 and 4, normal wire (green) to terminal 13,
check wire (red) to terminal 15, positive wire (gray) to terminal 18, negative wire (white, present only
on the panic button with key reset) to terminal 17.
6)
Mount the panic button.
2.8 I
NSTALLING THE
M
ICROPHONE
(
OPTIONAL
)
The MobileView microphone (Figure 21) is typically
mounted in the head sign area by the driver. Refer to
the instructions provided with the microphone for
installation procedures. A two-conductor shielded
microphone cable and a twisted pair power cable (18
AWG wire is recommended) must be routed from the
microphone to the DVR location. The shielded wire is
attached at the microphone end only. A service loop
should be left at the microphone end.
Figure 19. Panic button with key reset
Figure 20. Panic button without key reset
Figure 21. MobileView microphone