CHAPTER 8: COMMUNICATIONS
MODBUS MEMORY MAP
MM3 MOTOR MANAGER 3 – INSTRUCTION MANUAL
8–21
30164
163
00A3
Message buffer characters
39 and 40
---
---
ASCII
F10
---
30165
164
00A4
...Reserved...
...
...
...
...
...
↓
↓
↓
↓
↓
↓
↓
↓
↓
30176
175
00AF
...Reserved...
...
...
...
...
...
30177
176
00B0
Second mod file number
---
---
---
F1
---
30178
177
00B1
Third mod file number
---
---
---
F1
---
30179
178
00B2
Fourth mod file number
---
---
---
F1
---
30180
179
00B3
Fifth mod file number
---
---
---
F1
---
30181
180
00B4
...Reserved...
...
...
...
...
...
↓
↓
↓
↓
↓
↓
↓
↓
↓
30256
255
00FF
...Reserved...
...
...
...
...
...
User definable data (read only actual values)
30257
256
0100
User definable data 0000
30258
257
0101
User definable data 0001
30259
258
0102
User definable data 0002
30260
259
0103
User definable data 0003
30261
260
0104
User definable data 0004
30262
261
0105
User definable data 0005
30263
262
0106
User definable data 0006
30264
263
0107
User definable data 0007
30265
264
0108
User definable data 0008
30266
265
0109
User definable data 0009
30267
266
010A
User definable data 000A
30268
267
010B
User definable data 000B
30269
268
010C
User definable data 000C
30270
269
010D
User definable data 000D
30271
270
010E
User definable data 000E
30272
271
010F
User definable data 000F
↓
↓
↓
↓
↓
↓
↓
↓
↓
30376
375
0177
User definable data 0077
Setpoint values (holding registers) addresses - 1000 to 1FFF
Motor identification (read/write setpoints)
44097
4096
1000
Motor name characters 1
and 2
32 to
127
1
ASCII
F10
"MO"
44098
4097
1001
Motor name characters 3
and 4
32 to
127
1
ASCII
F10
"TO"
44099
4098
1002
Motor name characters 5
and 6
32 to
127
1
ASCII
F10
"R "
44100
4099
1003
Motor name characters 7
and 8
32 to
127
1
ASCII
F10
" "
44101
4100
1004
Motor name characters 9
and 10
32 to
127
1
ASCII
F10
" "
Table 8–2: Modbus Memory Map (Sheet 6 of 28)
Modicon
Address
Description
Range
Step
Units Format
Default
dec.
hex
* – Maximum setpoint value and 65535 represent OFF; ** – 1/phase current scale factor
×
A; *** – 101
represents unlimited;
† – Minimum setpoint value represents OFF; ~ – 0.1
×
A when high resolution mode is disabled;
0.01
×
A when enabled
Содержание MM3
Страница 8: ...vi MM3 MOTOR MANAGER 3 INSTRUCTION MANUAL TABLE OF CONTENTS ...
Страница 11: ...CHAPTER 1 INTRODUCTION OVERVIEW MM3 MOTOR MANAGER 3 INSTRUCTION MANUAL 1 3 Figure 1 1 Functional block diagram ...
Страница 18: ...1 10 MM3 MOTOR MANAGER 3 INSTRUCTION MANUAL TECHNICAL SPECIFICATIONS CHAPTER 1 INTRODUCTION ...
Страница 80: ...4 18 MM3 MOTOR MANAGER 3 INSTRUCTION MANUAL CHASSIS MOUNT UNITS CHAPTER 4 SOFTWARE ...
Страница 124: ...5 44 MM3 MOTOR MANAGER 3 INSTRUCTION MANUAL S7 TESTING CHAPTER 5 SETPOINTS ...
Страница 198: ...8 54 MM3 MOTOR MANAGER 3 INSTRUCTION MANUAL MODBUS MEMORY MAP CHAPTER 8 COMMUNICATIONS ...
Страница 220: ...10 14 MM3 MOTOR MANAGER 3 INSTRUCTION MANUAL GE MULTILIN WARRANTY CHAPTER 10 MISCELLANEOUS ...